Home Medical Page 4

Industry: Medical

  • EM1300 Series

    Input Range: 100-240V ac
    Output Range: 12-56V
    Power: 230-310W
    Form Factor: Medical desktop adaptor
    Cooling Method: Convection
    Certifications: UL60601-1, TUV EN60601-1, IEC60601-1, CB, CE, FCC

  • EM1331 Series

    Input Range: 90-264V ac
    Output Range: 12-56V
    Power: 230-330W
    Form Factor: Desktop adapter
    Cooling Method: Convection
    Certifications: IEC/EN/UL62368-1

  • EM1450 Series

    Input Range: 100-240V ac
    Output Range: 19-56V
    Power: 450-500W
    Form Factor: Desktop adapter
    Cooling Method: Convection
    Certifications: IEC/EN60601-1, UL62368-1, EN60601-1-2

  • FC15M Flexicharge Series

    Input Range: 90-264V ac
    Output Range: Configurable 3-24V
    Power: 1500W
    Form Factor: Plug-in / desktop
    Cooling Method: Convection
    Certifications: IEC/EN60335-2-29, IEC/EN60601-1

  • FCM30K Series

    Input Range: 187-528V ac, 3-phase
    Output Range: 48-60V adjustable (54.5V nominal) + 5V standby
    Power: 30,000W
    Form Factor: Shelf
    Cooling Method: Smart variable-speed fans
    Certifications: UL/IEC/EN 62368-1, CE, RoHS, EN61000

  • FM05D200P

    Rated Current: 5 A
    Rated Voltage: 200 V dc
    Frequency Range: DC
    Leakage Current: <1 mA
    Form Factor: PCB mount, metal housing
    Certifications: IEC/UL 60950, RoHS, CE

  • FM10/20-100 Series

    Rated Current: 10-20 A
    Rated Voltage: 75 V dc
    Frequency Range: DC
    Leakage Current: <1 mA
    Form Factor: PCB mount plastic module
    Certifications: IEC/UL 60950, RoHS

  • FM10D200P

    Rated Current: 10 A
    Rated Voltage: 200 V dc
    Frequency Range: DC
    Leakage Current: <1 mA
    Form Factor: PCB mount, metal housing
    Certifications: IEC/UL 60950, RoHS, CE

  • FM30R Series

    Rated Current: 30 A
    Rated Voltage: 80 V dc
    Frequency Range: DC
    Leakage Current: <1 mA
    Form Factor: Chassis mount, metal housing
    Certifications: IEC/UL 60950, RoHS, CE

  • FMAB NEO Series

    Rated Current: 1-60 A
    Rated Voltage: 250 V ac
    Frequency Range: 50-60 Hz
    Leakage Current: <1 mA (industrial) Form Factor: Chassis mount (various case sizes) Certifications: UL, VDE, CE, UKCA, RoHS

  • FMBB NEO Series

    Rated Current: 1-36 A
    Rated Voltage: 250 V ac
    Frequency Range: 50-60 Hz
    Leakage Current: <0.5 mA (standard), <5 µA (medical M5), <80 µA (medical M80) Form Factor: Chassis mount, metal housing Certifications: UL, VDE, CE, UKCA, RoHS

  • FMW-41 Series

    Rated Current: 1-10 A
    Rated Voltage: 250 V ac
    Frequency Range: 50-60 Hz
    Leakage Current: <0.25 mA (standard), <5 µA (medical M5), <80 µA (medical M80) Form Factor: Chassis mount (nickel-plated steel) Certifications: UL, VDE, CE, UKCA, RoHS

  • GHA300F Series

    Input Range: 90-264V ac.
    Output Range: 12-48V.
    Power: 300W.
    Form Factor: 3″x5″ open frame.
    Cooling Method: Convection / Forced Air / Conduction.
    Certifications: UL60950-1, UL62368-1, ANSI/AAMI ES60601-1, EN62368-1, EN60601-1

  • GHA500F Series

    Input Range: 90-264V ac.
    Output Range: 12-56V.
    Power: 500-504W.
    Form Factor: 3″x5″ open frame.
    Cooling Method: Conduction / Convection / Forced Air.
    Certifications: UL60950-1, UL62368-1, ANSI/AAMI ES60601-1, EN62368-1, EN60601-1

  • GHA700F Series

    Input Range: 85-264V ac.
    Output Range: 12-56V.
    Power: 650-701W.
    Form Factor: 3″x5″ open frame.
    Cooling Method: Conduction / Convection / Forced Air.
    Certifications: UL62368-1, ANSI/AAMI ES60601-1, EN62368-1, EN60601-1, EN61558-2-16

  • HCA3500TF Series

    Input Range: 180-528V ac 3-phase.
    Output Range: 48-65V.
    Power: 3500W.
    Form Factor: Enclosed 1.5U.
    Cooling Method: Conduction .
    Certifications: UL62368-1, EN62368-1, CSA62368-1