Relec Electronics supplies chassis mount DC-DC converters for industrial, railway, automotive, e-mobility, telecom and instrumentation systems. The range includes compact low-power units through to 10 kW converters, with input options extending from low-voltage batteries to 1100 Vdc systems.
Available products include isolated, bidirectional and high-voltage converters in enclosed, Eurocard and baseplate-cooled formats. Selected models provide wide input ranges, CAN communication, regulated outputs, reverse-polarity protection and protection against overvoltage, overcurrent and excessive temperatures. Railway options meet standards including EN 50155, EN 50121 and EN 45545-2.
Our engineers can help define the required input range, output voltage, isolation, power rating, cooling method and communication interface. Browse the range or contact Relec for technical selection and integration support.
Showing 1–16 of 31 results
Input Range: 6-58V dc
Output Range: 12-58V
Power: 3000W
Form Factor: Enclosed baseplate module
Cooling Method: Conduction via baseplate
Certifications: RoHS, Designed to meet MIL-STD-810G
Input Range: 9-63.2V dc
Output Range: 12V-48V
Power: 750W
Form Factor: Enclosed chassis
Cooling Method: Baseplate conduction
Certifications: RoHS, IEC 60068-2-27/64
Input Range: 12-60V dc
Output Range: 9-16V dc
Power: 3,000W
Form Factor: Enclosed automotive unit
Cooling Method: Conduction
Certifications: RoHS, IP6K9K
Input Range: 16.8-138V dc
Output Range: 500V
Power: 6000-10000W
Form Factor: Enclosed chassis
Cooling Method: Internal fan
Certifications: EN62368-1, EN50155, EN45545-2
Input Range: 43-160V dc
Output Range: 12-48V
Power: 600W
Form Factor: Chassis Mount
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN50155, EN45545-2
Input Range: 14-160V dc
Output Range: 5V-54V
Power: 200W
Form Factor: Half-brick
Cooling Method: Baseplate conduction
Certifications: EN50155, EN45545-2, UL62368-1
Input Range: 180 -425 Vdc
Output Range: 5-48V
Power: 300W
Form Factor: Half-brick module
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 16.8-160V dc
Output Range: 12V-54V
Power: 300W
Form Factor: Chassis mount
Cooling Method: Baseplate conduction
Certifications: EN50155, EN45545, UL62368-1
Input Range: 14.4-154V dc
Output Range: 12V-48V
Power: 120W
Form Factor: 3U Eurocard
Cooling Method: Natural convection
Certifications: EN50155, EN45545-2, EN62368-1
Input Range: 180-425V dc
Output Range: 5-48V
Power: 150W
Form Factor: Chassis Mount / Din Rail Mount
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 14.4-144 Vdc
Output Range: 24 – 110 Vdc
Power: 1000W
Form Factor: Chassis Mount
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN62368-1,EN50155 / EN45545-2 RoHS
Input Range: 14.4-154V dc
Output Range: 24V-110V
Power: 2000W
Form Factor: Enclosed chassis
Cooling Method: Internal forced air
Certifications: EN62368-1, EN50155, EN45545-2
Input Range: 14.4-30 Vdc / 21.6-47 Vdc / 28.8-60 Vdc / 43.2-90 Vdc / 66-144 Vdc
Output Range: 24-110 Vdc
Power: 500W
Form Factor: Chassis Mount
Cooling Method: Baseplate conduction
Certifications: EN62368-1, EN50155, EN45545-2
Input Range: 14-160V dc
Output Range: 12V-48V
Power: 100W
Form Factor: Chassis Mount
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN50155, EN45545-2
Input Range: 14.4-144V dc
Output Range: 5V-48V dc
Power: 100-140W
Form Factor: 3U Eurocard / chassis mount
Cooling Method: Natural convection
Certifications: EN50155, EN45545-2, EN62368-1
Input Range: 400-1100V dc
Output Range: 24-110V
Power: 280W
Form Factor: Enclosed module
Cooling Method: Natural convection
Certifications: EN62368-1, EN50155, EN50121-3-2
Tell us about your project and we’ll help you find the right-fit solution, fast.