Showing 1–16 of 40 results
Input Range: 85-264V ac / 120-370V dc.
Output Range: 380-393V dc.
Power: 1600W.
Form Factor: Full-brick module.
Cooling Method: Baseplate conduction.
Certifications: UL62368, cUL62368, TUV EN62368, UKCA
Input Range: 85-264V ac.
Output Range: 330-400V dc adjustable.
Power: 1400-2400W.
Form Factor: Full-brick module.
Cooling Method: Baseplate conduction.
Certifications: UL62368-1, CSA 62368-1, EN62368-1
Input Range: 90-264V ac / 120-370V dc.
Output Range: 12-48V.
Power: 100W .
Form Factor: Ultra-low profile full-brick .
Cooling Method: Convection .
Certifications: IEC/EN/UL 62368-1, EN55032 Class B, CISPR/FCC Class B
Input Range: 90-264V ac / 120-370V dc.
Output Range: 12-54V.
Power: 150W.
Form Factor: Ultra-low profile full-brick .
Cooling Method: Baseplate cooled convection .
Certifications: IEC/EN/UL 62368-1, EN55032 Class B, CISPR/FCC Class B
Input Range: 90-264V ac.
Output Range: 12-54V.
Power: 300W .
Form Factor: Half brick, 116.8 x 85.0 x 19.7 mm.
Cooling Method: Baseplate conduction.
Certifications: IEC/EN/UL62368-1, EN55032-B, FCC Class B
Input Range: 90-264V ac
Output Range: 12-48V
Power: 70W
Form Factor: Half-brick module
Cooling Method: Baseplate conduction, convection
Certifications: IEC/EN/UL62368-1
Input Range: 85-264V ac / 120-370V dc
Output Range: 5-48V
Power: 25W
Form Factor: Open frame / Encapsulated / PCB mount
Cooling Method: Convection
Certifications: IEC/EN/UL62368-1, IEC/EN60335-1
Input Range: 90-264V ac / 120-370V dc
Output Range: 5-48V
Power: 40W
Form Factor: Open frame / Encapsulated / Wafer
Cooling Method: Natural convection
Certifications: IEC/EN/UL62368-1, IEC/EN60335-1
Input Range: 90-264V ac.
Output Range: 5-48V.
Power: 60W.
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368-1, EN55032 Class B
Input Range: 85-305V ac / 120-430V dc.
Output Range: 5-24V.
Power: 20W.
Form Factor: Compact PCB module.
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368, CE
Input Range: 85-305V ac / 120-430V dc.
Output Range: 3.3-24V.
Power: 8.6-10W.
Form Factor: PCB / Chassis / DIN-Rail .
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368, IEC61558
Input Range: 85-305V ac / 120-430V dc.
Output Range: 3.3-24V.
Power: 10W.
Form Factor: PCB, chassis or DIN-rail module.
Cooling Method: Convection.
Certifications: IEC62368, UL62368, EN62368, CE, RoHS
Input Range: 85-305V ac / 120-430V dc.
Output Range: 5-24V.
Power: 15W.
Form Factor: Compact PCB module.
Cooling Method: Convection.
Certifications: CE, TUV
Input Range: 85-305V ac / 120-430V dc.
Output Range: 5-24V.
Power: 15W.
Form Factor: 1”x2” compact PCB module.
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368, CE, RoHS
Input Range: 85-305V ac / 120-430V dc
Output Range: 3.3-24V
Power: 5W
Form Factor: PCB / wired / DIN-rail mount
Cooling Method: Convection
Certifications: IEC62368, UL62368, EN62368, CE, TUV
Input Range: 90-264V ac.
Output Range: 12-48V.
Power: 300W.
Form Factor: 3″x5″ open frame.
Cooling Method: Convection / Forced Air / Conduction.
Certifications: UL60950-1, UL62368-1, ANSI/AAMI ES60601-1, EN62368-1, EN60601-1
Tell us about your project and we’ll help you find the right-fit solution, fast.