Showing 1–16 of 63 results
Input Range: 85-264V ac.
Output Range: 24-48V.
Power: 600-604.8W.
Form Factor: Enclosed 1U.
Cooling Method: Forced air .
Certifications: UL62368-1, EN62368-1, ANSI/AAMI ES60601-1, EN60601-1
Input Range: 85-264V ac / 120-370V dc.
Output Range: 380-393V dc.
Power: 1600W.
Form Factor: Full-brick module.
Cooling Method: Baseplate conduction.
Certifications: UL62368, cUL62368, TUV EN62368, UKCA
Input Range: 100-122V ac .
Output Range: 393V dc .
Power: 75W.
Form Factor: Quarter-brick module.
Cooling Method: Baseplate conduction.
Certifications: UL/cUL 60950, TUV EN60950
Input Range: 100-122V ac .
Output Range: 393V dc .
Power: 150W.
Form Factor: Three-quarter-brick module.
Cooling Method: Baseplate conduction.
Certifications: UL/cUL 60950, TUV EN60950
Input Range: 85-264V ac .
Output Range: 393V dc .
Power: 720W.
Form Factor: Three-quarter-brick module.
Cooling Method: Baseplate conduction.
Certifications: UL/cUL 60950, TUV EN60950
Input Range: 90-264V ac / 120-370V dc.
Output Range: 12-48V.
Power: 100W .
Form Factor: Ultra-low profile full-brick .
Cooling Method: Convection .
Certifications: IEC/EN/UL 62368-1, EN55032 Class B, CISPR/FCC Class B
Input Range: 90-264V ac / 120-370V dc.
Output Range: 12-54V.
Power: 150W.
Form Factor: Ultra-low profile full-brick .
Cooling Method: Baseplate cooled convection .
Certifications: IEC/EN/UL 62368-1, EN55032 Class B, CISPR/FCC Class B
Input Range: 90-264V ac.
Output Range: 12-54V.
Power: 300W .
Form Factor: Half brick, 116.8 x 85.0 x 19.7 mm.
Cooling Method: Baseplate conduction.
Certifications: IEC/EN/UL62368-1, EN55032-B, FCC Class B
Input Range: 90-264V ac
Output Range: 12-48V
Power: 70W
Form Factor: Half-brick module
Cooling Method: Baseplate conduction, convection
Certifications: IEC/EN/UL62368-1
Input Range: 90-264V ac.
Output Range: 28.5V or 57.5V.
Power: 300W.
Form Factor: IP67 enclosed module.
Cooling Method: Conduction
Input Range: 85-264V ac / 120-370V dc
Output Range: 12-48V
Power: 130W
Form Factor: 2” x 3” open-frame
Cooling Method: Convection / Forced-air
Certifications: IEC/EN/UL62368-1, EN55032 Class B
Input Range: 90-264V ac
Output Range: 12-48V
Power: 150W
Form Factor: 2” x 4” open frame
Cooling Method: Natural convection / Base cooling
Certifications: IEC/EN60335-1, IEC/EN60601-1, IEC/EN/UL62368-1
Input Range: 90-264V ac.
Output Range: 12-48V.
Power: 300W.
Form Factor: 3”x5” Open Frame / Covered.
Cooling Method: Convection or Forced Air.
Certifications: IEC60601-1, UL60601-1, EN55011 Class B
Input Range: 90-264V ac.
Output Range: 12-48V.
Power: 300W.
Form Factor: 3”x5” with baseplate or cover.
Cooling Method: Convection or Forced Air.
Certifications: IEC/EN/UL 62368-1, EN 55032, EN 55022
Input Range: 90-264V ac
Output Range: 12-48V
Power: 400W
Form Factor: 3” x 5” open frame
Cooling Method: Convection / Forced-air
Certifications: IEC/EN/UL62368-1, EN55032 Class B
Input Range: 90-264V ac
Output Range: 12-48V
Power: 500W
Form Factor: 3” x 5” open frame
Cooling Method: Convection / Forced-air
Certifications: IEC/EN/UL60601-1, IEC/EN/UL62368-1, EN55032 Class B
Tell us about your project and we’ll help you find the right-fit solution, fast.