Showing 17–32 of 97 results
Input Range: 43-160V dc
Output Range: 12-48V
Power: 300W
Form Factor: Half-brick module
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 180 -425 Vdc
Output Range: 5-48V
Power: 300W
Form Factor: Half-brick module
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 9-36V / 18-75V / 43-160V dc
Output Range: 3.3-48V
Power: 300W
Form Factor: Half-brick
Cooling Method: Conduction / free air convection
Certifications: UL62368-1, IEC62368-1, EN55032
Input Range: 43-160V dc
Output Range: 5-48V
Power: 300W
Form Factor: Half-brick
Cooling Method: Conduction / free air convection
Certifications: UL60950-1, EN50155, EN45545-2
Input Range: 9-36V dc / 18-75V dc
Output Range: 3.3-48V
Power: 33-50W
Form Factor: Half-brick
Cooling Method: Free air convection / conduction
Certifications: UL60950-1, EN60950-1, IEC60950-1, CE
Input Range: 16.8-160V dc
Output Range: 12V-54V
Power: 300W
Form Factor: Chassis mount
Cooling Method: Baseplate conduction
Certifications: EN50155, EN45545, UL62368-1
Input Range: 14.4-154V dc
Output Range: 12V-48V
Power: 120W
Form Factor: 3U Eurocard
Cooling Method: Natural convection
Certifications: EN50155, EN45545-2, EN62368-1
Input Range: 66-160V dc
Output Range: 3.3-24V
Power: 100W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: IEC/EN/UL62368-1, EN50155, EN61373
Input Range: 9-36V dc / 18-75V dc
Output Range: 3.3-24V
Power: 100W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: IEC/EN/UL62368-1, EN55032
Input Range: 12-160 Vdc
Output Range: 5V-54V
Power: 100W
Form Factor: Quarter-brick
Cooling Method: Baseplate conduction
Certifications: EN62368-1, EN50155, EN45545-2
Input Range: 180 -425 Vdc
Output Range: 5-48V
Power: 150W
Form Factor: Quarter-brick
Cooling Method: Baseplate conduction
Certifications: EN62368-1, EN50155
Input Range: 180-425V dc
Output Range: 5-48V
Power: 150W
Form Factor: Chassis Mount / Din Rail Mount
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 9-36V / 18-75V dc
Output Range: 5-48V
Power: 150W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: IEC/EN/UL62368-1, EN55032
Input Range: 43-160V dc
Output Range: 3.3-48V
Power: 150W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: UL60950-1, EN50155, EN45545-2, CE
Input Range: 9-75V dc / 18-150V dc
Output Range: 5V-54V
Power: 150W
Form Factor: Quarter-brick
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN50155, EN45545-2
Input Range: 14-160V dc
Output Range: 5-48V
Power: 30-50W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: UL62368-1, IEC62368-1, EN50155, EN45545-2
Tell us about your project and we’ll help you find the right-fit solution, fast.