From 1 W plugtops to 24 kW rack-mount systems.

AC-DC Power Supplies

Relec supplies a comprehensive range of AC-DC power supplies for industrial, medical, railway, telecom, instrumentation and commercial applications. Our portfolio includes enclosed, open frame, DIN rail, desktop, plugtop, PCB mount, configurable and conduction-cooled power supplies from manufacturers including Cosel, Cincon, Advanced Energy, Adel System, Chinfa, EDAC Power, Vox Power, Cotek, Aipu Power and Calex and Liteon. With power ratings ranging from compact low-power solutions to high-power rack-mount systems, Relec provides expert technical support to help customers select the right AC-DC power supply for their application.

Power (W)

Showing 49–64 of 247 results

  • CFM100M Series

    Input Range: 80-264V ac
    Output Range: 12-48V
    Power: 100W
    Form Factor: Open-frame 2” x 4”, chassis, DIN-rail,
    Cooling Method: Convection or forced air
    Certifications: IEC/EN/UL60601-1, IEC/EN/UL62368-1, EN60335-1, CE, RoHS

  • CFM130M Series

    Input Range: 80-264V ac
    Output Range: 12-48V
    Power: 130W
    Form Factor: Open-frame, baseplate or covered module
    Cooling Method: Convection or forced air
    Certifications: IEC60601-1, EN60601-1, EN60335-1, EN55011 Class B

  • CFM130S Series

    Input Range: 85-264V ac / 120-370V dc
    Output Range: 12-48V
    Power: 130W
    Form Factor: 2” x 3” open-frame
    Cooling Method: Convection / Forced-air
    Certifications: IEC/EN/UL62368-1, EN55032 Class B

  • CFM150S Series

    Input Range: 90-264V ac
    Output Range: 12-48V
    Power: 150W
    Form Factor: 2” x 4” open frame
    Cooling Method: Natural convection / Base cooling
    Certifications: IEC/EN60335-1, IEC/EN60601-1, IEC/EN/UL62368-1

  • CFM200M Series

    Input Range: 80-264V ac
    Output Range: 12-48V
    Power: 200W
    Form Factor: Open-frame 2” x 4”, chassis, DIN-rail, PCB mount options
    Cooling Method: Convection or forced air
    Certifications: IEC/EN/UL60601-1, IEC/EN/UL62368-1, EN60335-1, CE, RoHS

  • CFM25S Series

    Input Range: 85-264V ac / 120-370V dc
    Output Range: 5-48V
    Power: 25W
    Form Factor: Open frame / Encapsulated / PCB mount
    Cooling Method: Convection
    Certifications: IEC/EN/UL62368-1, IEC/EN60335-1

  • CFM300M Series

    Input Range: 90-264V ac.
    Output Range: 12-48V.
    Power: 300W.
    Form Factor: 3”x5” Open Frame / Covered.
    Cooling Method: Convection or Forced Air.
    Certifications: IEC60601-1, UL60601-1, EN55011 Class B

  • CFM300S Series

    Input Range: 90-264V ac.
    Output Range: 12-48V.
    Power: 300W.
    Form Factor: 3”x5” with baseplate or cover.
    Cooling Method: Convection or Forced Air.
    Certifications: IEC/EN/UL 62368-1, EN 55032, EN 55022

  • CFM400S Series

    Input Range: 90-264V ac
    Output Range: 12-48V
    Power: 400W
    Form Factor: 3” x 5” open frame
    Cooling Method: Convection / Forced-air
    Certifications: IEC/EN/UL62368-1, EN55032 Class B

  • CFM40M Series

    Input Range: 90-264V ac.
    Output Range: 3.3-48V.
    Power: 40W.
    Form Factor: 2”x3” Open Frame / PCB / Covered.
    Cooling Method: Convection.
    Certifications: IEC60601-1, EN60601-1, UL60950-1, EN60950-1, EN55011, EN55022

  • CFM40S Series

    Input Range: 90-264V ac.
    Output Range: 3.3-48V.
    Power: 40W.
    Form Factor: 2”x4” Open Frame / PCB / Covered.
    Cooling Method: Convection.
    Certifications: IEC/EN/UL 62368-1, EN 55032 Class B

  • CFM41S Series

    Input Range: 90-264V ac / 120-370V dc
    Output Range: 5-48V
    Power: 40W
    Form Factor: Open frame / Encapsulated / Wafer
    Cooling Method: Natural convection
    Certifications: IEC/EN/UL62368-1, IEC/EN60335-1

  • CFM500M Series

    Input Range: 90-264V ac
    Output Range: 12-48V
    Power: 500W
    Form Factor: 3” x 5” open frame
    Cooling Method: Convection / Forced-air
    Certifications: IEC/EN/UL60601-1, IEC/EN/UL62368-1, EN55032 Class B

  • CFM500S Series

    Input Range: 90-264V ac
    Output Range: 12-48V
    Power: 500W
    Form Factor: 3” x 5” open frame
    Cooling Method: Convection / Forced-air
    Certifications: IEC/EN/UL62368-1, EN55032 Class B

  • CFM600S Series

    Input Range: 80-264V ac
    Output Range: 12-48V
    Power: 600W
    Form Factor: 3” x 5” open frame
    Cooling Method: Convection/ Conduction Plate / Forced-air
    Certifications: IEC/EN 60335-1, EN 61000-3-2, EN 55032, IEC/EN/UL 62368-1

  • CFM60M Series

    Input Range: 90-264V ac.
    Output Range: 5-48V.
    Power: 60W.
    Form Factor: 2”x4” Open Frame / Covered.
    Cooling Method: Convection.
    Certifications: IEC60601-1, EN60601-1, UL60950-1, EN60950-1, EN55011, EN55022