Input Range: 90-264V ac.
Output Range: 12-48V.
Power: 300W.
Form Factor: 3”x5” Open Frame / Covered.
Cooling Method: Convection or Forced Air.
Certifications: IEC60601-1, UL60601-1, EN55011 Class B
Input Range: 90-264V ac.
Output Range: 12-48V.
Power: 300W.
Form Factor: 3”x5” with baseplate or cover.
Cooling Method: Convection or Forced Air.
Certifications: IEC/EN/UL 62368-1, EN 55032, EN 55022
Input Range: 90-264V ac
Output Range: 12-48V
Power: 400W
Form Factor: 3” x 5” open frame
Cooling Method: Convection / Forced-air
Certifications: IEC/EN/UL62368-1, EN55032 Class B
Input Range: 90-264V ac.
Output Range: 3.3-48V.
Power: 40W.
Form Factor: 2”x3” Open Frame / PCB / Covered.
Cooling Method: Convection.
Certifications: IEC60601-1, EN60601-1, UL60950-1, EN60950-1, EN55011, EN55022
Input Range: 90-264V ac.
Output Range: 3.3-48V.
Power: 40W.
Form Factor: 2”x4” Open Frame / PCB / Covered.
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368-1, EN 55032 Class B
Input Range: 90-264V ac / 120-370V dc
Output Range: 5-48V
Power: 40W
Form Factor: Open frame / Encapsulated / Wafer
Cooling Method: Natural convection
Certifications: IEC/EN/UL62368-1, IEC/EN60335-1
Input Range: 90-264V ac
Output Range: 12-48V
Power: 500W
Form Factor: 3” x 5” open frame
Cooling Method: Convection / Forced-air
Certifications: IEC/EN/UL60601-1, IEC/EN/UL62368-1, EN55032 Class B
Input Range: 90-264V ac
Output Range: 12-48V
Power: 500W
Form Factor: 3” x 5” open frame
Cooling Method: Convection / Forced-air
Certifications: IEC/EN/UL62368-1, EN55032 Class B
Input Range: 80-264V ac
Output Range: 12-48V
Power: 600W
Form Factor: 3” x 5” open frame
Cooling Method: Convection/ Conduction Plate / Forced-air
Certifications: IEC/EN 60335-1, EN 61000-3-2, EN 55032, IEC/EN/UL 62368-1
Input Range: 90-264V ac.
Output Range: 5-48V.
Power: 60W.
Form Factor: 2”x4” Open Frame / Covered.
Cooling Method: Convection.
Certifications: IEC60601-1, EN60601-1, UL60950-1, EN60950-1, EN55011, EN55022
Input Range: 90-264V ac.
Output Range: 3.3-48V.
Power: 60W.
Form Factor: 2” x 4” open frame.
Cooling Method: Convection cooled.
Certifications: IEC/EN/UL 62368-1, EN 55032 Class B
Input Range: 90-264V ac.
Output Range: 5-48V.
Power: 60W.
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368-1, EN55032 Class B
Input Range: 90-264V ac / 120-370V dc.
Output Range: 12-48V.
Power: 80W.
Form Factor: 2”x3” open frame module.
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368-1, IEC/EN 60335-1, EN55032 Class B, CISPR/FCC Class B
Input Range: 85-264V ac
Output Range: 1-205V
Power: 1000W
Form Factor: 1U U-channel modular
Cooling Method: Natural convection
Certifications: IEC60601-1, IEC62368-1, SEMI F47, MIL-STD-810G
Input Range: 85-264V ac
Output Range: 1-58V configurable
Power: Up to 1800W
Form Factor: Modular 1U supply
Cooling Method: Convection
Certifications: IEC60601-1, IEC60950-1, IEC62368-1, CE
Input Range: 85-264V ac
Output Range: 1V-58V configurable
Power: 600W
Form Factor: Modular 6-slot, 1U 264 x 164 x 40 mm
Cooling Method: Convection fanless
Certifications: IEC/UL/EN60601-1, IEC/UL/EN62368-1, EN61010, CE, RoHS