Input Range: 90-305V ac
Output Range: 24V
Power: 120W
Form Factor: DIN-rail module
Cooling Method: Natural convection
Certifications: EN62368-1, EN60950-1, EN60335-2-29, EN54-4
Input Range: 90-305V ac
Output Range: 12V / 24V selectable
Power: 120 – 240 W
Form Factor: DIN-rail
Cooling Method: Natural convection
Certifications: EN62368-1
Input Range: 90-305V ac
Output Range: 12V / 24V selectable
Power: 280W
Form Factor: DIN-rail module
Cooling Method: Natural convection
Certifications: EN62368-1, EN60950-1, UL60950-1, EN60335-2-29, EN54-4
Input Range: 90-305V ac
Output Range: 48V
Power: 600W
Form Factor: DIN-rail module
Cooling Method: Natural convection
Certifications: EN62368-1, UL60950-1, EN60950-1, EN60335-2-29, EN54-4
Input Range: 21-75V dc
Output Range: 27.6V
Power: 240W
Form Factor: DIN-rail module
Cooling Method: Natural convection
Certifications: EN62368-1, EN61010-1
Input Range: 90-264V ac / 120-370V dc.
Output Range: 12-48V.
Power: 100W .
Form Factor: Ultra-low profile full-brick .
Cooling Method: Convection .
Certifications: IEC/EN/UL 62368-1, EN55032 Class B, CISPR/FCC Class B
Input Range: 90-264V ac / 120-370V dc.
Output Range: 12-54V.
Power: 150W.
Form Factor: Ultra-low profile full-brick .
Cooling Method: Baseplate cooled convection .
Certifications: IEC/EN/UL 62368-1, EN55032 Class B, CISPR/FCC Class B
Input Range: 90-264V ac.
Output Range: 12-54V.
Power: 300W .
Form Factor: Half brick, 116.8 x 85.0 x 19.7 mm.
Cooling Method: Baseplate conduction.
Certifications: IEC/EN/UL62368-1, EN55032-B, FCC Class B
Input Range: 90-264V ac
Output Range: 12-48V
Power: 70W
Form Factor: Half-brick module
Cooling Method: Baseplate conduction, convection
Certifications: IEC/EN/UL62368-1
Input Range: 90-264V ac.
Output Range: 28.5V or 57.5V.
Power: 300W.
Form Factor: IP67 enclosed module.
Cooling Method: Conduction
Input Range: 80-264V ac
Output Range: 12-48V
Power: 100W
Form Factor: Open-frame 2” x 4”, chassis, DIN-rail,
Cooling Method: Convection or forced air
Certifications: IEC/EN/UL60601-1, IEC/EN/UL62368-1, EN60335-1, CE, RoHS
Input Range: 80-264V ac
Output Range: 12-48V
Power: 130W
Form Factor: Open-frame, baseplate or covered module
Cooling Method: Convection or forced air
Certifications: IEC60601-1, EN60601-1, EN60335-1, EN55011 Class B
Input Range: 85-264V ac / 120-370V dc
Output Range: 12-48V
Power: 130W
Form Factor: 2” x 3” open-frame
Cooling Method: Convection / Forced-air
Certifications: IEC/EN/UL62368-1, EN55032 Class B
Input Range: 90-264V ac
Output Range: 12-48V
Power: 150W
Form Factor: 2” x 4” open frame
Cooling Method: Natural convection / Base cooling
Certifications: IEC/EN60335-1, IEC/EN60601-1, IEC/EN/UL62368-1
Input Range: 80-264V ac
Output Range: 12-48V
Power: 200W
Form Factor: Open-frame 2” x 4”, chassis, DIN-rail, PCB mount options
Cooling Method: Convection or forced air
Certifications: IEC/EN/UL60601-1, IEC/EN/UL62368-1, EN60335-1, CE, RoHS
Input Range: 85-264V ac / 120-370V dc
Output Range: 5-48V
Power: 25W
Form Factor: Open frame / Encapsulated / PCB mount
Cooling Method: Convection
Certifications: IEC/EN/UL62368-1, IEC/EN60335-1