Home Power AC-DC Power Supplies
From 1 W plugtops to 24 kW rack-mount systems.

AC-DC Power Supplies

  • AEA1000F Series

    Input Range: 85-264V ac.
    Output Range: 24-48V.
    Power: 1000-1008W.
    Form Factor: Enclosed 1U.
    Cooling Method: Forced air .
    Certifications: UL62368-1, EN62368-1, ANSI/AAMI ES60601-1, EN60601-1

  • AEA600F Series

    Input Range: 85-264V ac.
    Output Range: 24-48V.
    Power: 600-604.8W.
    Form Factor: Enclosed 1U.
    Cooling Method: Forced air .
    Certifications: UL62368-1, EN62368-1, ANSI/AAMI ES60601-1, EN60601-1

  • AEA800F Series

    Input Range: 85-264V ac.
    Output Range: 24-48V.
    Power: 800-808W.
    Form Factor: Enclosed 1U.
    Cooling Method: Forced air .
    Certifications: UL62368-1, EN62368-1, ANSI/AAMI ES60601-1, EN60601-1

  • AIQ00ZPFC Series

    Input Range: 100-122V ac .
    Output Range: 393V dc .
    Power: 75W.
    Form Factor: Quarter-brick module.
    Cooling Method: Baseplate conduction.
    Certifications: UL/cUL 60950, TUV EN60950

  • AME Series

    Input Range: 85-264V ac
    Output Range: 3.3-100V dc (configurable)
    Power: 400-1200W
    Form Factor: Modular 1U configurable
    Cooling Method: Forced air (internal fan)
    Certifications: UL62368-1, EN60601-1, ANSI/AAMI ES60601-1, CE, UKCA

  • CFM100M Series

    Input Range: 80-264V ac
    Output Range: 12-48V
    Power: 100W
    Form Factor: Open-frame 2” x 4”, chassis, DIN-rail,
    Cooling Method: Convection or forced air
    Certifications: IEC/EN/UL60601-1, IEC/EN/UL62368-1, EN60335-1, CE, RoHS

  • CFM130M Series

    Input Range: 80-264V ac
    Output Range: 12-48V
    Power: 130W
    Form Factor: Open-frame, baseplate or covered module
    Cooling Method: Convection or forced air
    Certifications: IEC60601-1, EN60601-1, EN60335-1, EN55011 Class B

  • CFM200M Series

    Input Range: 80-264V ac
    Output Range: 12-48V
    Power: 200W
    Form Factor: Open-frame 2” x 4”, chassis, DIN-rail, PCB mount options
    Cooling Method: Convection or forced air
    Certifications: IEC/EN/UL60601-1, IEC/EN/UL62368-1, EN60335-1, CE, RoHS

  • CFM300M Series

    Input Range: 90-264V ac.
    Output Range: 12-48V.
    Power: 300W.
    Form Factor: 3”x5” Open Frame / Covered.
    Cooling Method: Convection or Forced Air.
    Certifications: IEC60601-1, UL60601-1, EN55011 Class B

  • CFM40M Series

    Input Range: 90-264V ac.
    Output Range: 3.3-48V.
    Power: 40W.
    Form Factor: 2”x3” Open Frame / PCB / Covered.
    Cooling Method: Convection.
    Certifications: IEC60601-1, EN60601-1, UL60950-1, EN60950-1, EN55011, EN55022

  • CFM500M Series

    Input Range: 90-264V ac
    Output Range: 12-48V
    Power: 500W
    Form Factor: 3” x 5” open frame
    Cooling Method: Convection / Forced-air
    Certifications: IEC/EN/UL60601-1, IEC/EN/UL62368-1, EN55032 Class B

  • CFM60M Series

    Input Range: 90-264V ac.
    Output Range: 5-48V.
    Power: 60W.
    Form Factor: 2”x4” Open Frame / Covered.
    Cooling Method: Convection.
    Certifications: IEC60601-1, EN60601-1, UL60950-1, EN60950-1, EN55011, EN55022

  • Coolx1000 Series

    Input Range: 85-264V ac
    Output Range: 1-205V
    Power: 1000W
    Form Factor: 1U U-channel modular
    Cooling Method: Natural convection
    Certifications: IEC60601-1, IEC62368-1, SEMI F47, MIL-STD-810G

  • Coolx1800 Series

    Input Range: 85-264V ac
    Output Range: 1-58V configurable
    Power: Up to 1800W
    Form Factor: Modular 1U supply
    Cooling Method: Convection
    Certifications: IEC60601-1, IEC60950-1, IEC62368-1, CE

  • Coolx600 Series

    Input Range: 85-264V ac
    Output Range: 1V-58V configurable
    Power: 600W
    Form Factor: Modular 6-slot, 1U 264 x 164 x 40 mm
    Cooling Method: Convection fanless
    Certifications: IEC/UL/EN60601-1, IEC/UL/EN62368-1, EN61010, CE, RoHS

  • CXLA100F Series

    Input Range: 90-264V ac
    Output Range: 12-24V
    Power: 100W
    Form Factor: Open frame
    Cooling Method: Convection
    Certifications: IEC60601-1, EN62368-1

Compare Power Products