  • CFM130S Series

    Input Range: 85-264V ac / 120-370V dc
    Output Range: 12-48V
    Power: 130W
    Form Factor: 2” x 3” open-frame
    Cooling Method: Convection / Forced-air
    Certifications: IEC/EN/UL62368-1, EN55032 Class B

  • CFM600S Series

    Input Range: 80-264V ac
    Output Range: 12-48V
    Power: 600W
    Form Factor: 3” x 5” open frame
    Cooling Method: Convection/ Conduction Plate / Forced-air
    Certifications: IEC/EN 60335-1, EN 61000-3-2, EN 55032, IEC/EN/UL 62368-1

  • CHB150W12 Series

    Input Range: 14-160V dc
    Output Range: 5-48V
    Power: 150W
    Form Factor: Half-brick
    Cooling Method: Baseplate conduction
    Certifications: UL62368-1, IEC62368-1, EN50155, EN45545-2

  • CHB150W8 Series

    Input Range: 9-75V dc
    Output Range: 12-48V
    Power: 150W
    Form Factor: Half-brick
    Cooling Method: Baseplate conduction
    Certifications: UL62368, RoHS

  • CHB200W12 Series

    Input Range: 14-160V dc
    Output Range: 12-48V
    Power: 200W
    Form Factor: Half-brick module
    Cooling Method: Baseplate conduction
    Certifications: UL62368-1, EN62368-1, EN50155

  • CHB300-300S Series

    Input Range: 43-160V dc
    Output Range: 12-48V
    Power: 300W
    Form Factor: Half-brick module
    Cooling Method: Baseplate conduction / Forced air
    Certifications: UL62368-1, EN62368-1, EN50155

  • CHB300-300Sxx-CMFCD Series

    Input Range: 180 -425 Vdc
    Output Range: 5-48V
    Power: 300W
    Form Factor: Half-brick module
    Cooling Method: Baseplate conduction / Forced air
    Certifications: UL62368-1, EN62368-1, EN50155

  • CQB100W Series

    Input Range: 9-36V dc / 18-75V dc
    Output Range: 3.3-24V
    Power: 100W
    Form Factor: Quarter-brick
    Cooling Method: Conduction / free air convection
    Certifications: IEC/EN/UL62368-1, EN55032

  • CQB100W14 Series

    Input Range: 12-160 Vdc
    Output Range: 5V-54V
    Power: 100W
    Form Factor: Quarter-brick
    Cooling Method: Baseplate conduction
    Certifications: EN62368-1, EN50155, EN45545-2

  • CQB150-300S Series

    Input Range: 180 -425 Vdc
    Output Range: 5-48V
    Power: 150W
    Form Factor: Quarter-brick
    Cooling Method: Baseplate conduction
    Certifications: EN62368-1, EN50155

  • CQB150-300Sxx-CMFCD Series

    Input Range: 180-425V dc
    Output Range: 5-48V
    Power: 150W
    Form Factor: Chassis Mount / Din Rail Mount
    Cooling Method: Baseplate conduction / Forced air
    Certifications: UL62368-1, EN62368-1, EN50155

  • CQB150W8 Series

    Input Range: 9-75V dc / 18-150V dc
    Output Range: 5V-54V
    Power: 150W
    Form Factor: Quarter-brick
    Cooling Method: Baseplate conduction
    Certifications: UL62368-1, EN50155, EN45545-2

  • CQB75-300S Series

    Input Range: 180-450 Vdc
    Output Range: 3.3-48V
    Power: 75W
    Form Factor: Quarter-brick module
    Cooling Method: Baseplate conduction / Forced air
    Certifications: UL62368-1, EN62368-1, EN50155

  • CXLDA120F

    Rated Current: 10 A (12 Vdc), 5 A (24 Vdc), 2.5 A (48 Vdc)
    Rated Voltage: 12 Vdc, 24 Vdc, 48 Vdc
    Frequency Range: 47–63 Hz
    Leakage Current: 0.75 mA max (240 Vac, 60 Hz)
    Form Factor: DIN rail mount
    Certifications: UL61010-1, UL61010-2-201, UL62368-1, EN61010-1/EN61010-2-201 (planned), EN62368-1 (planned), RoHS (2011/65/EU), SEMI F47, EN/BS EN 55032 (CISPR32) Class B, FCC Class B

  • CXLDA240F

    Rated Current: 10 A (24 Vdc), 5 A (48 Vdc)
    Rated Voltage: 24 Vdc, 48 Vdc
    Frequency Range: 47–63 Hz
    Leakage Current: 0.75 mA max (240 Vac, 60 Hz)
    Form Factor: DIN rail power supply
    Certifications: UL61010-1, UL61010-2-201, UL62368-1, EN/BS EN 55032 (CISPR32) Class B, FCC Class B, IEC61000-3-2 Class A, IEC61000-3-3, RoHS (2011/65/EU), SEMI F47

  • CXLDA480F

    Rated Current: 20 A (24 Vdc), 10 A (48 Vdc)
    Rated Voltage: 24 Vdc, 48 Vdc
    Frequency Range: 47–63 Hz
    Leakage Current: 0.75 mA max (240 Vac, 60 Hz)
    Form Factor: DIN rail power supply
    Certifications: UL61010-1, UL61010-2-201, UL62368-1, EN/BS EN 55032 (CISPR32) Class B, FCC Class B, IEC61000-3-2 Class A, IEC61000-3-3, RoHS (2011/65/EU), SEMI F47