Showing 33–48 of 123 results
Input Range: 85-264V ac / 120-370V dc
Output Range: 12-48V
Power: 130W
Form Factor: 2” x 3” open-frame
Cooling Method: Convection / Forced-air
Certifications: IEC/EN/UL62368-1, EN55032 Class B
Input Range: 80-264V ac
Output Range: 12-48V
Power: 600W
Form Factor: 3” x 5” open frame
Cooling Method: Convection/ Conduction Plate / Forced-air
Certifications: IEC/EN 60335-1, EN 61000-3-2, EN 55032, IEC/EN/UL 62368-1
Input Range: 14-160V dc
Output Range: 5-48V
Power: 150W
Form Factor: Half-brick
Cooling Method: Baseplate conduction
Certifications: UL62368-1, IEC62368-1, EN50155, EN45545-2
Input Range: 9-75V dc
Output Range: 12-48V
Power: 150W
Form Factor: Half-brick
Cooling Method: Baseplate conduction
Certifications: UL62368, RoHS
Input Range: 14-160V dc
Output Range: 12-48V
Power: 200W
Form Factor: Half-brick module
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 43-160V dc
Output Range: 12-48V
Power: 300W
Form Factor: Half-brick module
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 180 -425 Vdc
Output Range: 5-48V
Power: 300W
Form Factor: Half-brick module
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 9-36V dc / 18-75V dc
Output Range: 3.3-24V
Power: 100W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: IEC/EN/UL62368-1, EN55032
Input Range: 12-160 Vdc
Output Range: 5V-54V
Power: 100W
Form Factor: Quarter-brick
Cooling Method: Baseplate conduction
Certifications: EN62368-1, EN50155, EN45545-2
Input Range: 180 -425 Vdc
Output Range: 5-48V
Power: 150W
Form Factor: Quarter-brick
Cooling Method: Baseplate conduction
Certifications: EN62368-1, EN50155
Input Range: 180-425V dc
Output Range: 5-48V
Power: 150W
Form Factor: Chassis Mount / Din Rail Mount
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 9-75V dc / 18-150V dc
Output Range: 5V-54V
Power: 150W
Form Factor: Quarter-brick
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN50155, EN45545-2
Input Range: 180-450 Vdc
Output Range: 3.3-48V
Power: 75W
Form Factor: Quarter-brick module
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Rated Current: 10 A (12 Vdc), 5 A (24 Vdc), 2.5 A (48 Vdc)
Rated Voltage: 12 Vdc, 24 Vdc, 48 Vdc
Frequency Range: 47–63 Hz
Leakage Current: 0.75 mA max (240 Vac, 60 Hz)
Form Factor: DIN rail mount
Certifications: UL61010-1, UL61010-2-201, UL62368-1, EN61010-1/EN61010-2-201 (planned), EN62368-1 (planned), RoHS (2011/65/EU), SEMI F47, EN/BS EN 55032 (CISPR32) Class B, FCC Class B
Rated Current: 10 A (24 Vdc), 5 A (48 Vdc)
Rated Voltage: 24 Vdc, 48 Vdc
Frequency Range: 47–63 Hz
Leakage Current: 0.75 mA max (240 Vac, 60 Hz)
Form Factor: DIN rail power supply
Certifications: UL61010-1, UL61010-2-201, UL62368-1, EN/BS EN 55032 (CISPR32) Class B, FCC Class B, IEC61000-3-2 Class A, IEC61000-3-3, RoHS (2011/65/EU), SEMI F47
Rated Current: 20 A (24 Vdc), 10 A (48 Vdc)
Rated Voltage: 24 Vdc, 48 Vdc
Frequency Range: 47–63 Hz
Leakage Current: 0.75 mA max (240 Vac, 60 Hz)
Form Factor: DIN rail power supply
Certifications: UL61010-1, UL61010-2-201, UL62368-1, EN/BS EN 55032 (CISPR32) Class B, FCC Class B, IEC61000-3-2 Class A, IEC61000-3-3, RoHS (2011/65/EU), SEMI F47