Showing 193–208 of 369 results
Input Range: 187-528V ac, 3-phase
Output Range: 48-60V adjustable (54.5V nominal) + 5V standby
Power: 10,000W
Form Factor: Front-end
Cooling Method: Smart variable-speed fans
Certifications: UL/IEC/TUV 62368-1, CE, RoHS, EN61000
Input Range: 187-528V ac, 3-phase
Output Range: 48-60V adjustable (54.5V nominal) + 5V standby
Power: 30,000W
Form Factor: Shelf
Cooling Method: Smart variable-speed fans
Certifications: UL/IEC/EN 62368-1, CE, RoHS, EN61000
Input Range: 90-265V ac.
Output Range: 86-157V dc.
Power: 3000W.
Form Factor: 19” rack module.
Cooling Method: Internal forced air.
Certifications: EN62368, EN61000-6-2, EN61000-6-4, EN61000-6-5
Input Range: 90-135V ac / 180-264V ac
Output Range: 48V
Power: 180W
Form Factor: DIN-rail module
Cooling Method: Convection
Certifications: UL508, EN61010-2-201, EN60950, EN50178
Input Range: 90-135V ac / 180-264V ac
Output Range: 48V
Power: 350W
Form Factor: DIN-rail module
Cooling Method: Convection
Certifications: UL508, EN61010-2-201, EN60950, EN50178
Input Range: 90-135V ac / 180-264V ac
Output Range: 48V
Power: 600W
Form Factor: DIN-rail module
Cooling Method: Convection
Certifications: UL508, EN61010-2-201, EN60950, EN50178
Input Range: 90-135V ac / 180-264V ac
Output Range: 5V
Power: 35W
Form Factor: DIN-rail module
Cooling Method: Convection
Certifications: UL508, EN61010-2-201, EN60950, EN50178
Input Range: 400V ac 3-phase.
Output Range: 104.5-137.75V dc.
Power: up to 11.2kW.
Form Factor: Cabinet with modular subrack.
Cooling Method: Forced convection with natural convection .
Certifications: IEC/EN62368-1, IEC/EN61204-7, IEC/EN61000-6-2, IEC/EN61000-6-4, IEC/EN61000-6-5
Rated Current: 5 A
Rated Voltage: 200 V dc
Frequency Range: DC
Leakage Current: <1 mA
Form Factor: PCB mount, metal housing
Certifications: IEC/UL 60950, RoHS, CE
Rated Current: 10-20 A
Rated Voltage: 75 V dc
Frequency Range: DC
Leakage Current: <1 mA
Form Factor: PCB mount plastic module
Certifications: IEC/UL 60950, RoHS
Rated Current: 10 A
Rated Voltage: 200 V dc
Frequency Range: DC
Leakage Current: <1 mA
Form Factor: PCB mount, metal housing
Certifications: IEC/UL 60950, RoHS, CE
Rated Current: 30 A
Rated Voltage: 80 V dc
Frequency Range: DC
Leakage Current: <1 mA
Form Factor: Chassis mount, metal housing
Certifications: IEC/UL 60950, RoHS, CE
Rated Current: 1-60 A
Rated Voltage: 250 V ac
Frequency Range: 50-60 Hz
Leakage Current: <1 mA (industrial)
Form Factor: Chassis mount (various case sizes)
Certifications: UL, VDE, CE, UKCA, RoHS
Rated Current: 10-20 A
Rated Voltage: 250 V ac
Frequency Range: 50-60 Hz
Leakage Current: <2.1 mA
Form Factor: DIN-rail mount, metal housing
Certifications: UL, VDE, CE, UKCA, RoHS
Rated Current: 3-20 A
Rated Voltage: 480 V ac
Frequency Range: 50-60 Hz
Leakage Current: <0.5 mA
Form Factor: DIN-rail mount, metal housing
Certifications: UL, VDE, CE, UKCA, RoHS
Rated Current: 6-1100 A
Rated Voltage: 480/520 V ac
Frequency Range: 50-60 Hz
Leakage Current: <15 mA
Form Factor: Chassis mount, metal housing
Certifications: UL, VDE, CE, UKCA, RoHS