Home Cosel

Brand: Cosel

Showing 1–16 of 71 results

  • AEA1000F Series

    Input Range: 85-264V ac.
    Output Range: 24-48V.
    Power: 1000-1008W.
    Form Factor: Enclosed 1U.
    Cooling Method: Forced air .
    Certifications: UL62368-1, EN62368-1, ANSI/AAMI ES60601-1, EN60601-1

  • AEA600F Series

    Input Range: 85-264V ac.
    Output Range: 24-48V.
    Power: 600-604.8W.
    Form Factor: Enclosed 1U.
    Cooling Method: Forced air .
    Certifications: UL62368-1, EN62368-1, ANSI/AAMI ES60601-1, EN60601-1

  • AEA800F Series

    Input Range: 85-264V ac.
    Output Range: 24-48V.
    Power: 800-808W.
    Form Factor: Enclosed 1U.
    Cooling Method: Forced air .
    Certifications: UL62368-1, EN62368-1, ANSI/AAMI ES60601-1, EN60601-1

  • AME Series

    Input Range: 85-264V ac
    Output Range: 3.3-100V dc (configurable)
    Power: 400-1200W
    Form Factor: Modular 1U configurable
    Cooling Method: Forced air (internal fan)
    Certifications: UL62368-1, EN60601-1, ANSI/AAMI ES60601-1, CE, UKCA

  • DCS1400B Series

    Input Range: 16.8-137.5V dc
    Output Range: 24V-110V dc
    Power: 1400W
    Form Factor: Enclosed chassis mount
    Cooling Method: Convection / conduction

  • ECDA Series

    Input Range: 85-305V ac .
    Output Range: 12V / 28V.
    Power: 500W / 700W / 1000W.
    Form Factor: Baseplate mount.
    Cooling Method: Conductive cooling.
    Certifications: UL, IEC, EN62368-1, CE, UKCA, MIL-STD-461, MIL-STD-810H, MIL-STD-1399-300

  • FDA150F

    Rated Current: 10 A (5 Vdc), 4.2 A (12 Vdc), 3.4 A (15 Vdc), 2.1 A (24 Vdc), 1.1 A (48 Vdc)
    Rated Voltage: 5 Vdc, 12 Vdc, 15 Vdc, 24 Vdc, 48 Vdc
    Frequency Range: 47–440 Hz
    Leakage Current: 0.75 mA max (480 Vac, 60 Hz, full load)
    Form Factor: Enclosed, chassis mount
    Certifications: UL62368-1, C-UL (CAN/CSA-C22.2 No. 62368-1), EN62368-1, CE, UKCA, RoHS, SEMI F47, IEC61000-3-2 Class A, CISPR11 Class A, CISPR32 Class A

  • FDA200F

    Rated Current: 10 A (5 Vdc), 4.2 A (12 Vdc), 3.4 A (15 Vdc), 2.1 A (24 Vdc), 1.1 A (48 Vdc)
    Rated Voltage: 5 Vdc, 12 Vdc, 15 Vdc, 24 Vdc, 48 Vdc
    Frequency Range: 47–440 Hz
    Leakage Current: 0.75 mA max (480 Vac, 60 Hz, full load)
    Form Factor: Enclosed, chassis mount
    Certifications: UL62368-1, C-UL (CAN/CSA-C22.2 No. 62368-1), EN62368-1, CE, UKCA, RoHS, SEMI F47, IEC61000-3-2 Class A, CISPR11 Class A, CISPR32 Class A

  • FDA50F

    Rated Current: 10 A (5 Vdc), 4.2 A (12 Vdc), 3.4 A (15 Vdc), 2.1 A (24 Vdc), 1.1 A (48 Vdc)
    Rated Voltage: 5 Vdc, 12 Vdc, 15 Vdc, 24 Vdc, 48 Vdc
    Frequency Range: 47–440 Hz
    Leakage Current: 0.75 mA max (480 Vac, 60 Hz, full load)
    Form Factor: Enclosed, chassis mount
    Certifications: UL62368-1, C-UL (CAN/CSA-C22.2 No. 62368-1), EN62368-1, CE, UKCA, RoHS, SEMI F47, IEC61000-3-2 Class A, CISPR11 Class A, CISPR32 Class A

  • FDA75F

    Rated Current: 10 A (5 Vdc), 4.2 A (12 Vdc), 3.4 A (15 Vdc), 2.1 A (24 Vdc), 1.1 A (48 Vdc)
    Rated Voltage: 5 Vdc, 12 Vdc, 15 Vdc, 24 Vdc, 48 Vdc
    Frequency Range: 47–440 Hz
    Leakage Current: 0.75 mA max (480 Vac, 60 Hz, full load)
    Form Factor: Enclosed, chassis mount
    Certifications: UL62368-1, C-UL (CAN/CSA-C22.2 No. 62368-1), EN62368-1, CE, UKCA, RoHS, SEMI F47, IEC61000-3-2 Class A, CISPR11 Class A, CISPR32 Class A

  • GHA300F Series

    Input Range: 90-264V ac.
    Output Range: 12-48V.
    Power: 300W.
    Form Factor: 3″x5″ open frame.
    Cooling Method: Convection / Forced Air / Conduction.
    Certifications: UL60950-1, UL62368-1, ANSI/AAMI ES60601-1, EN62368-1, EN60601-1

  • GHA500F Series

    Input Range: 90-264V ac.
    Output Range: 12-56V.
    Power: 500-504W.
    Form Factor: 3″x5″ open frame.
    Cooling Method: Conduction / Convection / Forced Air.
    Certifications: UL60950-1, UL62368-1, ANSI/AAMI ES60601-1, EN62368-1, EN60601-1

  • GHA700F Series

    Input Range: 85-264V ac.
    Output Range: 12-56V.
    Power: 650-701W.
    Form Factor: 3″x5″ open frame.
    Cooling Method: Conduction / Convection / Forced Air.
    Certifications: UL62368-1, ANSI/AAMI ES60601-1, EN62368-1, EN60601-1, EN61558-2-16

  • HCA3500TF Series

    Input Range: 180-528V ac 3-phase.
    Output Range: 48-65V.
    Power: 3500W.
    Form Factor: Enclosed 1.5U.
    Cooling Method: Conduction .
    Certifications: UL62368-1, EN62368-1, CSA62368-1

  • HFA3500TF Series

    Input Range: 180-528V ac 3-phase.
    Output Range: 48-65V.
    Power: 3500-3510W.
    Form Factor: Enclosed 1U.
    Cooling Method: Forced air .
    Certifications: UL62368-1, EN62368-1, CSA62368-1

  • KH120F

    Rated Current: 5A
    Output Voltage: 24 Vdc
    Frequency Range: 45–66 Hz
    Leakage Current: 0.45 mA max (100 Vac), 0.75 mA max (240 Vac)
    Form Factor: DIN rail power supply
    Certifications: CE UKCA RoHS IEC61000-3-2 Class A FCC Class B CISPR22 Class B EN55011 Class B EN55022 Class B VCCI Class B

Compare Power Products