Relec Electronics supplies conduction and baseplate-cooled DC-DC converters for systems where airflow is restricted, fanless operation is required or environmental contaminants make forced-air cooling unsuitable. Heat transfers through the converter’s baseplate into a suitable heatsink, cold plate or equipment chassis.
The range includes half-brick, full-brick and enclosed converters delivering up to 3 kW. Products are available for industrial, railway, automotive, e-mobility, telecom, defence and medical applications. Selected models offer wide input ranges, high-voltage inputs, regulated outputs and compliance with standards including EN 50155, EN 45545-2 and IEC/EN/UL 62368-1.
Our engineers can help assess the input range, output voltage, isolation, thermal interface, baseplate temperature and required derating. Browse the range or contact Relec for product selection and integration support.
Showing 17–30 of 30 results
Input Range: 9-36V dc / 18-75V dc
Output Range: 3.3-48V
Power: 33-50W
Form Factor: Half-brick
Cooling Method: Free air convection / conduction
Certifications: UL60950-1, EN60950-1, IEC60950-1, CE
Input Range: 66-160V dc
Output Range: 3.3-24V
Power: 100W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: IEC/EN/UL62368-1, EN50155, EN61373
Input Range: 9-36V dc / 18-75V dc
Output Range: 3.3-24V
Power: 100W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: IEC/EN/UL62368-1, EN55032
Input Range: 12-160 Vdc
Output Range: 5V-54V
Power: 100W
Form Factor: Quarter-brick
Cooling Method: Baseplate conduction
Certifications: EN62368-1, EN50155, EN45545-2
Input Range: 16.8-137.5V dc
Output Range: 24V-110V dc
Power: 1400W
Form Factor: Enclosed chassis mount
Cooling Method: Convection / conduction
Input Range: 9-160V dc
Output Range: 3.3V-48V
Power: 40W
Form Factor: Encapsulated / DIN-rail module
Cooling Method: Conduction via baseplate
Certifications: EN50155, EN45545-2, UL62368-1
Input Range: 10-16V dc
Output Range: 28V dc
Power: 1100-2100W
Form Factor: Enclosed low-profile package
Cooling Method: Baseplate conduction
Certifications: Designed to meet MIL-STD-810G
Input Range: 9-36V
Output Range: 12-28V
Power: 360W
Form Factor: Half-brick
Cooling Method: Baseplate conduction
Certifications: UL60950, RoHS
Input Range: 9-36V dc
Output Range: 12-28V
Power: 500W
Form Factor: Half-brick
Cooling Method: Baseplate/heatsink conduction
Certifications: UL60950, RoHS
Input Range: 18-36V dc
Output Range: 3.3V-28V
Power: 75W
Form Factor: Chassis Mount
Cooling Method: Baseplate conduction
Certifications: UL60950-1, EN60950-1, RoHS
Input Range: 9-36V
Output Range: 12V
Power: 250W
Form Factor: Quarter-brick
Cooling Method: Baseplate conduction
Certifications: UL60950, RoHS
Input Range: 9-60V dc
Output Range: 56V
Power: 360W
Form Factor: Full-brick
Cooling Method: Baseplate conduction
Certifications: IEC/EN/UL60950-1, MIL-STD-810G
Input Range: 9-36V dc
Output Range: 12V-28V
Power: 360W
Form Factor: Chassis mount
Cooling Method: Conduction via baseplate
Certifications: Designed to meet UL/cUL 60950, IEC/EN 60950-1, MIL-STD-810G
Input Range: 33.6-160V dc
Output Range: 12V-48V
Power: 300W
Form Factor: Enclosed chassis
Cooling Method: Conduction via baseplate
Certifications: EN50155, EN45545-2, EN62368-1