Relec Electronics supplies DIN rail mount AC-DC power supplies for installation in industrial control panels, cabinets and distribution systems. The range includes compact low-power units, higher-power supplies, battery chargers and power-management modules for industrial, telecom, instrumentation, railway, broadcast and security applications.
Available options include universal and wide ac inputs, regulated DC outputs and convection-cooled designs with no external fan. Selected models provide battery monitoring, charging control, redundancy, communication interfaces and protection against overvoltage, overcurrent, short circuits and excessive temperatures.
Our engineers can help specify the correct input range, output voltage, power rating, mounting width and safety approvals for your system. Browse the range or contact Relec for technical selection and integration support.
Showing 49–64 of 65 results
Input Range: 90-135V ac / 180-264V ac
Output Range: 48V
Power: 180W
Form Factor: DIN-rail module
Cooling Method: Convection
Certifications: UL508, EN61010-2-201, EN60950, EN50178
Input Range: 90-135V ac / 180-264V ac
Output Range: 48V
Power: 350W
Form Factor: DIN-rail module
Cooling Method: Convection
Certifications: UL508, EN61010-2-201, EN60950, EN50178
Input Range: 90-135V ac / 180-264V ac
Output Range: 48V
Power: 600W
Form Factor: DIN-rail module
Cooling Method: Convection
Certifications: UL508, EN61010-2-201, EN60950, EN50178
Input Range: 90-135V ac / 180-264V ac
Output Range: 5V
Power: 35W
Form Factor: DIN-rail module
Cooling Method: Convection
Certifications: UL508, EN61010-2-201, EN60950, EN50178
Input Range: 400V ac 3-phase.
Output Range: 104.5-137.75V dc.
Power: up to 11.2kW.
Form Factor: Cabinet with modular subrack.
Cooling Method: Forced convection with natural convection .
Certifications: IEC/EN62368-1, IEC/EN61204-7, IEC/EN61000-6-2, IEC/EN61000-6-4, IEC/EN61000-6-5
Rated Current: 5A
Output Voltage: 24 Vdc
Frequency Range: 45–66 Hz
Leakage Current: 0.45 mA max (100 Vac), 0.75 mA max (240 Vac)
Form Factor: DIN rail power supply
Certifications: CE UKCA RoHS IEC61000-3-2 Class A FCC Class B CISPR22 Class B EN55011 Class B EN55022 Class B VCCI Class B
Rated Current: 10A
Output Voltage: 24 Vdc
Frequency Range: 45–66 Hz
Leakage Current: 0.45 mA max (100 Vac), 0.75 mA max (240 Vac)
Form Factor: DIN rail power supply
Certifications: CE UKCA RoHS IEC61000-3-2 Class A FCC Class B CISPR22 Class B EN55011 Class B EN55022 Class B VCCI Class B
Rated Current: 5 A, 2.3 A, 1.3 A
Output Voltage: 5 Vdc, 12 Vdc, 24 Vdc
Frequency Range: 45–440 Hz
Leakage Current: 0.45 mA max (100 Vac), 0.75 mA max (240 Vac)
Form Factor: DIN rail power supply
Certifications: CE UKCA RoHS IEC61000-3-2 Class A FCC Class B CISPR22 Class B EN55011 Class B EN55022 Class B VCCI Class B
Rated Current: 20A, 10A
Output Voltage: 24 Vdc, 48Vdc
Frequency Range: 45–66 Hz
Leakage Current: 0.45 mA max (100 Vac), 0.75 mA max (240 Vac)
Form Factor: DIN rail power supply
Certifications: CE UKCA RoHS IEC61000-3-2 Class A FCC Class B CISPR22 Class B EN55011 Class B EN55022 Class B VCCI Class B
Rated Current: 4.5 A, 2.5 A
Output Voltage: 12 Vdc, 24 Vdc
Frequency Range: 45–440 Hz
Leakage Current: 0.45 mA max (100 Vac), 0.75 mA max (240 Vac)
Form Factor: DIN rail power supply
Certifications: CE UKCA RoHS IEC61000-3-2 Class A FCC Class B CISPR22 Class B EN55011 Class B EN55022 Class B VCCI Class B
Rated Current: 6.8 A (12 Vdc), 3.8 A (24 Vdc)
Output Voltage: 12 Vdc, 24 Vdc
Frequency Range: 45–66 Hz
Leakage Current: 0.45 mA max (100 Vac), 0.75 mA max (240 Vac)
Form Factor: DIN rail power supply
Certifications: CE UKCA RoHS IEC61000-3-2 Class A FCC Class B CISPR22 Class B EN55011 Class B EN55022 Class B VCCI Class B
Output Voltage: 22 – 28.8 Vdc
PV module Open circuit voltage: 12 – 35
PV module power min: 30W
Form Factor: DIN-rail module
Cooling Method: Natural Convection
Certifications: EN IEC 62368-1: 2014/AC:2015; EN54-4 Fire Detection and fire alarm systems; 89/336/EEC; EMC Directive 2014/35/UE and Low voltage Directive 2014/35/UE; DIN41773 (Charging cycle); Emission: IEC 61000-6-4; Immunity: IEC 61000-6-2. CE
Input Range: 28Vac-72Vdc.
Output Range: 24V.
Power: up to 168W.
Form Factor: DIN-rail.
Cooling Method: Free air convection.
Certifications: EN61010-2-201, EMC 2014/30/EU, Low Voltage 2014/35/EU, RoHS
Input Range: 340-575 Vac
Output Range: 12-24V
Power: 120 W
Form Factor: Din Rail Mount
Cooling Method: Convection
Certifications: IEC/EN/UL62368-1, CE, RoHS
Input Range: 340-575 Vac
Output Range: 24-48V
Power: 240 W
Form Factor: Din Rail Mount
Cooling Method: Convection
Certifications: IEC/EN/UL62368-1, CE, RoHS
Input Range: 340-575 Vac
Output Range: 24-48V
Power: 480 W
Form Factor: Din Rail Mount
Cooling Method: Convection
Certifications: IEC/EN/UL62368-1, CE, RoHS