Showing 33–48 of 83 results
Input Range: 43-160V dc
Output Range: 5-48V
Power: 300W
Form Factor: Half-brick
Cooling Method: Conduction / free air convection
Certifications: UL60950-1, EN50155, EN45545-2
Input Range: 16.8-160V dc
Output Range: 12V-54V
Power: 300W
Form Factor: Chassis mount
Cooling Method: Baseplate conduction
Certifications: EN50155, EN45545, UL62368-1
Input Range: 14.4-154V dc
Output Range: 12V-48V
Power: 120W
Form Factor: 3U Eurocard
Cooling Method: Natural convection
Certifications: EN50155, EN45545-2, EN62368-1
Input Range: 66-160V dc
Output Range: 3.3-24V
Power: 100W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: IEC/EN/UL62368-1, EN50155, EN61373
Input Range: 12-160 Vdc
Output Range: 5V-54V
Power: 100W
Form Factor: Quarter-brick
Cooling Method: Baseplate conduction
Certifications: EN62368-1, EN50155, EN45545-2
Input Range: 43-160V dc
Output Range: 3.3-48V
Power: 150W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: UL60950-1, EN50155, EN45545-2, CE
Input Range: 9-75V dc / 18-150V dc
Output Range: 5V-54V
Power: 150W
Form Factor: Quarter-brick
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN50155, EN45545-2
Input Range: 14-160V dc
Output Range: 5-48V
Power: 30-50W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: UL62368-1, IEC62368-1, EN50155, EN45545-2
Input Range: 14-160V dc
Output Range: 5V-48V
Power: 50W
Form Factor: Half-brick, chassis mount
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN50155, EN45545-2
Input Range: 66-160V dc
Output Range: 3.3-24V
Power: 60W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: UL62368-1, IEC62368-1, EN50155
Input Range: 9-75V dc
Output Range: 12-48V
Power: 75W
Form Factor: Quarter-brick module
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 14.4-144 Vdc
Output Range: 24 – 110 Vdc
Power: 1000W
Form Factor: Chassis Mount
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN62368-1,EN50155 / EN45545-2 RoHS
Input Range: 14.4-154V dc
Output Range: 24V-110V
Power: 2000W
Form Factor: Enclosed chassis
Cooling Method: Internal forced air
Certifications: EN62368-1, EN50155, EN45545-2
Input Range: 14.4-30 Vdc / 21.6-47 Vdc / 28.8-60 Vdc / 43.2-90 Vdc / 66-144 Vdc
Output Range: 24-110 Vdc
Power: 500W
Form Factor: Chassis Mount
Cooling Method: Baseplate conduction
Certifications: EN62368-1, EN50155, EN45545-2
Input Range: 14-160V dc
Output Range: 12V-48V
Power: 100W
Form Factor: Chassis Mount
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN50155, EN45545-2
Input Range: 14.4-144V dc
Output Range: 5V-48V dc
Power: 100-140W
Form Factor: 3U Eurocard / chassis mount
Cooling Method: Natural convection
Certifications: EN50155, EN45545-2, EN62368-1