  • CHB300W-110S Series

    Input Range: 43-160V dc
    Output Range: 5-48V
    Power: 300W
    Form Factor: Half-brick
    Cooling Method: Conduction / free air convection
    Certifications: UL60950-1, EN50155, EN45545-2

  • CHR Series

    Input Range: 16.8-160V dc
    Output Range: 12V-54V
    Power: 300W
    Form Factor: Chassis mount
    Cooling Method: Baseplate conduction
    Certifications: EN50155, EN45545, UL62368-1

  • CLS-120 Series

    Input Range: 14.4-154V dc
    Output Range: 12V-48V
    Power: 120W
    Form Factor: 3U Eurocard
    Cooling Method: Natural convection
    Certifications: EN50155, EN45545-2, EN62368-1

  • CQB100-110S Series

    Input Range: 66-160V dc
    Output Range: 3.3-24V
    Power: 100W
    Form Factor: Quarter-brick
    Cooling Method: Conduction / free air convection
    Certifications: IEC/EN/UL62368-1, EN50155, EN61373

  • CQB100W14 Series

    Input Range: 12-160 Vdc
    Output Range: 5V-54V
    Power: 100W
    Form Factor: Quarter-brick
    Cooling Method: Baseplate conduction
    Certifications: EN62368-1, EN50155, EN45545-2

  • CQB150W-110S Series

    Input Range: 43-160V dc
    Output Range: 3.3-48V
    Power: 150W
    Form Factor: Quarter-brick
    Cooling Method: Conduction / free air convection
    Certifications: UL60950-1, EN50155, EN45545-2, CE

  • CQB150W8 Series

    Input Range: 9-75V dc / 18-150V dc
    Output Range: 5V-54V
    Power: 150W
    Form Factor: Quarter-brick
    Cooling Method: Baseplate conduction
    Certifications: UL62368-1, EN50155, EN45545-2

  • CQB50W12 Series

    Input Range: 14-160V dc
    Output Range: 5-48V
    Power: 30-50W
    Form Factor: Quarter-brick
    Cooling Method: Conduction / free air convection
    Certifications: UL62368-1, IEC62368-1, EN50155, EN45545-2

  • CQB50W12-72S-CMFC(D) Series

    Input Range: 14-160V dc
    Output Range: 5V-48V
    Power: 50W
    Form Factor: Half-brick, chassis mount
    Cooling Method: Baseplate conduction
    Certifications: UL62368-1, EN50155, EN45545-2

  • CQB60W-110S Series

    Input Range: 66-160V dc
    Output Range: 3.3-24V
    Power: 60W
    Form Factor: Quarter-brick
    Cooling Method: Conduction / free air convection
    Certifications: UL62368-1, IEC62368-1, EN50155

  • CQB75W8 Series

    Input Range: 9-75V dc
    Output Range: 12-48V
    Power: 75W
    Form Factor: Quarter-brick module
    Cooling Method: Baseplate conduction / Forced air
    Certifications: UL62368-1, EN62368-1, EN50155

  • CRS-1000 Series

    Input Range: 14.4-144 Vdc
    Output Range: 24 – 110 Vdc
    Power: 1000W
    Form Factor: Chassis Mount
    Cooling Method: Baseplate conduction
    Certifications: UL62368-1, EN62368-1,EN50155 / EN45545-2 RoHS

  • CRS-2000 Series

    Input Range: 14.4-154V dc
    Output Range: 24V-110V
    Power: 2000W
    Form Factor: Enclosed chassis
    Cooling Method: Internal forced air
    Certifications: EN62368-1, EN50155, EN45545-2

  • CRS-500 Series

    Input Range: 14.4-30 Vdc / 21.6-47 Vdc / 28.8-60 Vdc / 43.2-90 Vdc / 66-144 Vdc
    Output Range: 24-110 Vdc
    Power: 500W
    Form Factor: Chassis Mount
    Cooling Method: Baseplate conduction
    Certifications: EN62368-1, EN50155, EN45545-2

  • CRT100W12 Series

    Input Range: 14-160V dc
    Output Range: 12V-48V
    Power: 100W
    Form Factor: Chassis Mount
    Cooling Method: Baseplate conduction
    Certifications: UL62368-1, EN50155, EN45545-2

  • CTS-120 Series

    Input Range: 14.4-144V dc
    Output Range: 5V-48V dc
    Power: 100-140W
    Form Factor: 3U Eurocard / chassis mount
    Cooling Method: Natural convection
    Certifications: EN50155, EN45545-2, EN62368-1

Compare Power Products