Input Range: 90-264V ac.
Output Range: 3.3-48V.
Power: 60W.
Form Factor: 2” x 4” open frame.
Cooling Method: Convection cooled.
Certifications: IEC/EN/UL 62368-1, EN 55032 Class B
Input Range: 90-264V ac.
Output Range: 5-48V.
Power: 60W.
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368-1, EN55032 Class B
Input Range: 90-264V ac / 120-370V dc.
Output Range: 12-48V.
Power: 80W.
Form Factor: 2”x3” open frame module.
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368-1, IEC/EN 60335-1, EN55032 Class B, CISPR/FCC Class B
Input Range: 66-160V dc
Output Range: 12-48V
Power: 100W
Form Factor: Half-brick
Cooling Method: Conduction / free air convection
Certifications: UL60950-1, EN50155, CE
Input Range: 9-36V dc / 18-75V dc
Output Range: 3.3-48V
Power: 100W
Form Factor: Half-brick
Cooling Method: Conduction / free air convection
Certifications: UL62368-1, IEC62368-1, EN50155
Input Range: 14-160V dc
Output Range: 5-48V
Power: 150W
Form Factor: Half-brick
Cooling Method: Baseplate conduction
Certifications: UL62368-1, IEC62368-1, EN50155, EN45545-2
Input Range: 9-75V dc
Output Range: 12-48V
Power: 150W
Form Factor: Half-brick
Cooling Method: Baseplate conduction
Certifications: UL62368, RoHS
Input Range: 9-36V / 18-75V
Output Range: 5-48V
Power: 200W
Form Factor: Half-brick
Cooling Method: Conduction / free air convection
Certifications: UL62368-1, IEC62368-1, EN50155
Input Range: 43-160V dc
Output Range: 5V-48V
Power: 200W
Form Factor: Half-brick
Cooling Method: Baseplate conduction
Certifications: UL60950-1, EN50155, EN45545-2
Input Range: 14-160V dc
Output Range: 12-48V
Power: 200W
Form Factor: Half-brick module
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 14-160V dc
Output Range: 5V-54V
Power: 200W
Form Factor: Half-brick
Cooling Method: Baseplate conduction
Certifications: EN50155, EN45545-2, UL62368-1
Input Range: 43-160V dc
Output Range: 12-48V
Power: 300W
Form Factor: Half-brick module
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 180 -425 Vdc
Output Range: 5-48V
Power: 300W
Form Factor: Half-brick module
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 9-36V / 18-75V / 43-160V dc
Output Range: 3.3-48V
Power: 300W
Form Factor: Half-brick
Cooling Method: Conduction / free air convection
Certifications: UL62368-1, IEC62368-1, EN55032
Input Range: 43-160V dc
Output Range: 5-48V
Power: 300W
Form Factor: Half-brick
Cooling Method: Conduction / free air convection
Certifications: UL60950-1, EN50155, EN45545-2
Input Range: 9-36V dc / 18-75V dc
Output Range: 3.3-48V
Power: 33-50W
Form Factor: Half-brick
Cooling Method: Free air convection / conduction
Certifications: UL60950-1, EN60950-1, IEC60950-1, CE