Showing 145–160 of 391 results
Input Range: 14.4-144V dc
Output Range: 5V-48V dc
Power: 100-140W
Form Factor: 3U Eurocard / chassis mount
Cooling Method: Natural convection
Certifications: EN50155, EN45545-2, EN62368-1
Input Range: 400-1100V dc
Output Range: 24-110V
Power: 280W
Form Factor: Enclosed module
Cooling Method: Natural convection
Certifications: EN62368-1, EN50155, EN50121-3-2
Input Range: 90-264V ac
Output Range: 28.8-29.4V , 27.6V
Power: 300-960W
Form Factor: Chassis Mount
Cooling Method: Internal fan, two-speed control
Certifications: EN60335-1, EN60335-2-29, EN55022, EN61000
Input Range: 90-264V ac
Output Range: 12-24V
Power: 100W
Form Factor: Open frame
Cooling Method: Convection
Certifications: IEC60601-1, EN62368-1
Input Range: 90-264V ac
Output Range: 12-24V
Power: 150W
Form Factor: Open frame
Cooling Method: Convection
Certifications: IEC60601-1, EN62368-1
Rated Current: 10 A (12 Vdc), 5 A (24 Vdc), 2.5 A (48 Vdc)
Rated Voltage: 12 Vdc, 24 Vdc, 48 Vdc
Frequency Range: 47–63 Hz
Leakage Current: 0.75 mA max (240 Vac, 60 Hz)
Form Factor: DIN rail mount
Certifications: UL61010-1, UL61010-2-201, UL62368-1, EN61010-1/EN61010-2-201 (planned), EN62368-1 (planned), RoHS (2011/65/EU), SEMI F47, EN/BS EN 55032 (CISPR32) Class B, FCC Class B
Rated Current: 10 A (24 Vdc), 5 A (48 Vdc)
Rated Voltage: 24 Vdc, 48 Vdc
Frequency Range: 47–63 Hz
Leakage Current: 0.75 mA max (240 Vac, 60 Hz)
Form Factor: DIN rail power supply
Certifications: UL61010-1, UL61010-2-201, UL62368-1, EN/BS EN 55032 (CISPR32) Class B, FCC Class B, IEC61000-3-2 Class A, IEC61000-3-3, RoHS (2011/65/EU), SEMI F47
Rated Current: 20 A (24 Vdc), 10 A (48 Vdc)
Rated Voltage: 24 Vdc, 48 Vdc
Frequency Range: 47–63 Hz
Leakage Current: 0.75 mA max (240 Vac, 60 Hz)
Form Factor: DIN rail power supply
Certifications: UL61010-1, UL61010-2-201, UL62368-1, EN/BS EN 55032 (CISPR32) Class B, FCC Class B, IEC61000-3-2 Class A, IEC61000-3-3, RoHS (2011/65/EU), SEMI F47
Input Range: 85-305V ac / 120-430V dc.
Output Range: 5-24V.
Power: 20W.
Form Factor: Compact PCB module.
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368, CE
Input Range: 90-264 Vac
Output Range: 12-24V
Power: 30-60W
Form Factor: Din rail mount
Cooling Method: Convection
Rated Current: 1-10 A
Rated Voltage: 250 V ac
Frequency Range: 50-60 Hz
Leakage Current: <0.5 mA (standard), <5 µA (medical)
Form Factor: Panel mount (front/rear, screw or snap-in)
Certifications: UL, VDE, CQC, CE, UKCA, RoHS
Input Range: 16.8-137.5V dc
Output Range: 24V-110V dc
Power: 1400W
Form Factor: Enclosed chassis mount
Cooling Method: Convection / conduction
Input Range: 90 -305 Vac
Output Range: 12V
Power: 15W
Form Factor: DIN-rail Mount
Cooling Method: Convection
Certifications: EN62368-1
Input Range: 90-305V dc
Output Range: 12V
Power: 54 W
Form Factor: DIN-rail module
Cooling Method: Convection
Certifications: EN62368-1, EN50178
Input Range: 150-1500V dc
Output Range: 12-48V
Power: 30W
Form Factor: PCB mount
Cooling Method: Free air convection
Certifications: UL1741, CSA-C22.2, EN62109-1
Input Range: 150-1500V dc
Output Range: 12-48V
Power: 45W
Form Factor: PCB mount
Cooling Method: Free air convection
Certifications: UL1741, CSA-C22.2, EN62109-1