Input Range: 90-264V ac.
Output Range: 3.3-48V.
Power: 40W.
Form Factor: 2”x3” Open Frame / PCB / Covered.
Cooling Method: Convection.
Certifications: IEC60601-1, EN60601-1, UL60950-1, EN60950-1, EN55011, EN55022
Input Range: 90-264V ac.
Output Range: 3.3-48V.
Power: 40W.
Form Factor: 2”x4” Open Frame / PCB / Covered.
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368-1, EN 55032 Class B
Input Range: 90-264V ac / 120-370V dc
Output Range: 5-48V
Power: 40W
Form Factor: Open frame / Encapsulated / Wafer
Cooling Method: Natural convection
Certifications: IEC/EN/UL62368-1, IEC/EN60335-1
Input Range: 90-264V ac
Output Range: 12-48V
Power: 500W
Form Factor: 3” x 5” open frame
Cooling Method: Convection / Forced-air
Certifications: IEC/EN/UL60601-1, IEC/EN/UL62368-1, EN55032 Class B
Input Range: 90-264V ac
Output Range: 12-48V
Power: 500W
Form Factor: 3” x 5” open frame
Cooling Method: Convection / Forced-air
Certifications: IEC/EN/UL62368-1, EN55032 Class B
Input Range: 80-264V ac
Output Range: 12-48V
Power: 600W
Form Factor: 3” x 5” open frame
Cooling Method: Convection/ Conduction Plate / Forced-air
Certifications: IEC/EN 60335-1, EN 61000-3-2, EN 55032, IEC/EN/UL 62368-1
Input Range: 90-264V ac.
Output Range: 5-48V.
Power: 60W.
Form Factor: 2”x4” Open Frame / Covered.
Cooling Method: Convection.
Certifications: IEC60601-1, EN60601-1, UL60950-1, EN60950-1, EN55011, EN55022
Input Range: 90-264V ac.
Output Range: 3.3-48V.
Power: 60W.
Form Factor: 2” x 4” open frame.
Cooling Method: Convection cooled.
Certifications: IEC/EN/UL 62368-1, EN 55032 Class B
Input Range: 90-264V ac.
Output Range: 5-48V.
Power: 60W.
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368-1, EN55032 Class B
Input Range: 90-264V ac / 120-370V dc.
Output Range: 12-48V.
Power: 80W.
Form Factor: 2”x3” open frame module.
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368-1, IEC/EN 60335-1, EN55032 Class B, CISPR/FCC Class B
Input Range: 66-160V dc
Output Range: 12-48V
Power: 100W
Form Factor: Half-brick
Cooling Method: Conduction / free air convection
Certifications: UL60950-1, EN50155, CE
Input Range: 9-36V dc / 18-75V dc
Output Range: 3.3-48V
Power: 100W
Form Factor: Half-brick
Cooling Method: Conduction / free air convection
Certifications: UL62368-1, IEC62368-1, EN50155
Input Range: 14-160V dc
Output Range: 5-48V
Power: 150W
Form Factor: Half-brick
Cooling Method: Baseplate conduction
Certifications: UL62368-1, IEC62368-1, EN50155, EN45545-2
Input Range: 9-75V dc
Output Range: 12-48V
Power: 150W
Form Factor: Half-brick
Cooling Method: Baseplate conduction
Certifications: UL62368, RoHS
Input Range: 9-36V / 18-75V
Output Range: 5-48V
Power: 200W
Form Factor: Half-brick
Cooling Method: Conduction / free air convection
Certifications: UL62368-1, IEC62368-1, EN50155
Input Range: 43-160V dc
Output Range: 5V-48V
Power: 200W
Form Factor: Half-brick
Cooling Method: Baseplate conduction
Certifications: UL60950-1, EN50155, EN45545-2