Showing 1–16 of 31 results
Input Range: 6-58V dc
Output Range: 12-58V
Power: 3000W
Form Factor: Enclosed baseplate module
Cooling Method: Conduction via baseplate
Certifications: RoHS, Designed to meet MIL-STD-810G
Input Range: 9-63.2V dc
Output Range: 12V-48V
Power: 750W
Form Factor: Enclosed chassis
Cooling Method: Baseplate conduction
Certifications: RoHS, IEC 60068-2-27/64
Input Range: 9-32V dc
Output Range: 9-16V dc
Power: 3,000W
Form Factor: Enclosed automotive unit
Cooling Method: Conduction
Certifications: RoHS, IP6K9K
Input Range: 16.8-138V dc
Output Range: 500V
Power: 6000-10000W
Form Factor: Enclosed chassis
Cooling Method: Internal fan
Certifications: EN62368-1, EN50155, EN45545-2
Input Range: 43-160V dc
Output Range: 12-48V
Power: 600W
Form Factor: Chassis Mount
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN50155, EN45545-2
Input Range: 14-160V dc
Output Range: 5V-54V
Power: 200W
Form Factor: Half-brick
Cooling Method: Baseplate conduction
Certifications: EN50155, EN45545-2, UL62368-1
Input Range: 180 -425 Vdc
Output Range: 5-48V
Power: 300W
Form Factor: Half-brick module
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 16.8-160V dc
Output Range: 12V-54V
Power: 300W
Form Factor: Chassis mount
Cooling Method: Baseplate conduction
Certifications: EN50155, EN45545, UL62368-1
Input Range: 14.4-154V dc
Output Range: 12V-48V
Power: 120W
Form Factor: 3U Eurocard
Cooling Method: Natural convection
Certifications: EN50155, EN45545-2, EN62368-1
Input Range: 180-425V dc
Output Range: 5-48V
Power: 150W
Form Factor: Chassis Mount / Din Rail Mount
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 14.4-144 Vdc
Output Range: 24 – 110 Vdc
Power: 1000W
Form Factor: Chassis Mount
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN62368-1,EN50155 / EN45545-2 RoHS
Input Range: 14.4-154V dc
Output Range: 24V-110V
Power: 2000W
Form Factor: Enclosed chassis
Cooling Method: Internal forced air
Certifications: EN62368-1, EN50155, EN45545-2
Input Range: 14.4-30 Vdc / 21.6-47 Vdc / 28.8-60 Vdc / 43.2-90 Vdc / 66-144 Vdc
Output Range: 24-110 Vdc
Power: 500W
Form Factor: Chassis Mount
Cooling Method: Baseplate conduction
Certifications: EN62368-1, EN50155, EN45545-2
Input Range: 14-160V dc
Output Range: 12V-48V
Power: 100W
Form Factor: Chassis Mount
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN50155, EN45545-2
Input Range: 14.4-144V dc
Output Range: 5V-48V dc
Power: 100-140W
Form Factor: 3U Eurocard / chassis mount
Cooling Method: Natural convection
Certifications: EN50155, EN45545-2, EN62368-1
Input Range: 400-1100V dc
Output Range: 24-110V
Power: 280W
Form Factor: Enclosed module
Cooling Method: Natural convection
Certifications: EN62368-1, EN50155, EN50121-3-2
Tell us about your project and we’ll help you find the right-fit solution, fast.