Showing 65–80 of 233 results
Input Range: 90-264V ac.
Output Range: 5-48V.
Power: 60W.
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368-1, EN55032 Class B
Input Range: 90-264V ac / 120-370V dc.
Output Range: 12-48V.
Power: 80W.
Form Factor: 2”x3” open frame module.
Cooling Method: Convection.
Certifications: IEC/EN/UL 62368-1, IEC/EN 60335-1, EN55032 Class B, CISPR/FCC Class B
Input Range: 85-264V ac
Output Range: 1-205V
Power: 1000W
Form Factor: 1U U-channel modular
Cooling Method: Natural convection
Certifications: IEC60601-1, IEC62368-1, SEMI F47, MIL-STD-810G
Input Range: 85-264V ac
Output Range: 1-58V configurable
Power: Up to 1800W
Form Factor: Modular 1U supply
Cooling Method: Convection
Certifications: IEC60601-1, IEC60950-1, IEC62368-1, CE
Input Range: 85-264V ac
Output Range: 1V-58V configurable
Power: 600W
Form Factor: Modular 6-slot, 1U 264 x 164 x 40 mm
Cooling Method: Convection fanless
Certifications: IEC/UL/EN60601-1, IEC/UL/EN62368-1, EN61010, CE, RoHS
Input Range: 180 -425 Vdc
Output Range: 5-48V
Power: 150W
Form Factor: Quarter-brick
Cooling Method: Baseplate conduction
Certifications: EN62368-1, EN50155
Input Range: 9-36V / 18-75V dc
Output Range: 5-48V
Power: 150W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: IEC/EN/UL62368-1, EN55032
Input Range: 43-160V dc
Output Range: 3.3-48V
Power: 150W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: UL60950-1, EN50155, EN45545-2, CE
Input Range: 14-160V dc
Output Range: 5-48V
Power: 30-50W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: UL62368-1, IEC62368-1, EN50155, EN45545-2
Input Range: 14-160V dc
Output Range: 5V-48V
Power: 50W
Form Factor: Half-brick, chassis mount
Cooling Method: Baseplate conduction
Certifications: UL62368-1, EN50155, EN45545-2
Input Range: 66-160V dc
Output Range: 3.3-24V
Power: 60W
Form Factor: Quarter-brick
Cooling Method: Conduction / free air convection
Certifications: UL62368-1, IEC62368-1, EN50155
Input Range: 180-450 Vdc
Output Range: 3.3-48V
Power: 75W
Form Factor: Quarter-brick module
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 9-75V dc
Output Range: 12-48V
Power: 75W
Form Factor: Quarter-brick module
Cooling Method: Baseplate conduction / Forced air
Certifications: UL62368-1, EN62368-1, EN50155
Input Range: 90-264V ac
Output Range: 28.8-29.4V , 27.6V
Power: 300-960W
Form Factor: Chassis Mount
Cooling Method: Internal fan, two-speed control
Certifications: EN60335-1, EN60335-2-29, EN55022, EN61000
Input Range: 90-264V ac
Output Range: 12-24V
Power: 100W
Form Factor: Open frame
Cooling Method: Convection
Certifications: IEC60601-1, EN62368-1
Input Range: 90-264V ac
Output Range: 12-24V
Power: 150W
Form Factor: Open frame
Cooling Method: Convection
Certifications: IEC60601-1, EN62368-1
Tell us about your project and we’ll help you find the right-fit solution, fast.