S (47 - 440Hz) Series

Mains Input, Rugged AC DC Converter
Regulated, 1 or 2 Isolated Outputs
100W AC DC Converters
EN55022 / EN60950 Compliant
-25°C to +71°C Operation
3U x 12HP Eurocassette /19" - Chassis Mount options

    Sunit-image
 
 
 
 
 Part Number Input Range (VAC)  Vout (VDC)  Iout (A)  Eff% 
LS1001-7R
85 - 264VAC
 5.1V
16A
78
LS1301-7R 85 - 264VAC 12V  8A 83
 LS1501-7R 85 - 264VAC 15V  6.5A 84
LS1601-7R 85 - 264VAC 24V  4.2A 85
LS2320-7R 85 - 264VAC 12V / 12V 4.0A / 4.0A 80
LS2540-7R 85 - 264VAC 15V / 15V 3.2A / 3.2A 81
LS2660-7R 85 - 264VAC 24V / 24V 2.0A / 2.0A 81
Options
-9             -25°C to +71°C operation
P             Potentiometer
D0 - D9    Save data signal (See datasheet for options)
V0 - V3    AC Fail signal (See datasheet for options)
B1           Cooling plate standard case
Input voltage ranges from 8 to 385 VDC and 85 to 264 VAC, 47-440 Hz
1 or 2 isolated outputs up to 48 VDC
Class I equipment
RoHS lead solder exemption compliant
Extremely-wide input voltage range
Input over- and undervoltage lockout
Efficient input filter and built-in surge and transient suppression circuitry
Outputs: SELV, no-load, and short-circuit proof
No derating over entire operating temperature range
PCBs coated with protective lacquer
Very high reliability
The S Series AC-DC and DC-DC converters represents a broad
and flexible range of power supplies for use in advanced
electronic systems. Features include high efficiency, high
reliability, low output voltage noise and excellent dynamic
response to load/line changes. LS models can be powered by
DC or AC with a wide-input frequency range (without PFC).

The converter inputs are protected against surges and
transients. An input over- and undervoltage lockout circuitry
disables the outputs if the input voltage is outside of the
specified range. Certain types include an inrush current limiter
preventing circuit breakers and fuses from tripping at switch-on.

All outputs are open- and short-circuit proof and are protected
against overvoltages by means of built-in suppressor diodes.
The outputs can be inhibited by a logic signal applied to pin 18
(i). If the inhibit function is not used, pin 18 must be connected
with pin 14 to enable the outputs.

LED indicators display the status of the converter and allow for
visual monitoring of the system at any time.

Full input-to-output, input-to-case, output-to-case and output-tooutput
isolation is provided. The converters are designed and
built according to the international safety standards IEC/EN
60950 and EN50155. They have been approved by the safety
agencies TÜV and UL (for USA and Canada).

The case design allows operation at nominal load up to 71 °C in a
free-air ambient temperature. If forced cooling is provided, the
ambient temperature may exceed 71 °C, but the case temperature
must remain below 95 °C under all conditions.

A temperature sensor generates an inhibit signal, which disables
the outputs if the case temperature Tc exceeds the limit. The
outputs are automatically re-enabled when the temperature drops
below the limit.

Various options are available to adapt the converters to individual
applications.

The converters may either be plugged into a 19" rack system
according to IEC 60297-3, or be chassis mounted. They are ideally
suited for Railway applications
Sunit-Footprint-1Sunit-Footprint-2

 

 
 
 

 

Related Downloads

S Series Datasheet (439 Kb) S Series Datasheet
Mounting supports (400 Kb) Mounting supports
Cassette & Din Rail Temperature Sensor Datasheet (117 Kb) Cassette & Din Rail Temperature Sensor Datasheet
Mating connectors (221 Kb) Mating connectors
Front panels (96 Kb) Front panels
K&S Series Agency Approval (2776 Kb) K&S Series Agency Approval
S Series Rohs Certificate (396 Kb) S Series Rohs Certificate
Spacer

Copyright © 2012 Relec  | Site Map  | Terms & Conditions

Powered By Intergage | www.intergage.co.uk