Relec Electronics Ltd

 

ISO 9001


Tel:
+44 (0) 1929 555700
or Contact us here

M Series (AC)

Mains Input, Rugged AC DC Converter
Regulated, 1, 2 or 3 Isolated Outputs
50W AC DC Converters
EN55022 / EN60950 Compliant
-25°C to +71°C Operation
3U x 8HP Eurocassette /19" - Chassis Mount options

    Munit---Image
 
 
 
 
 Part Number Input Range (VAC)  Vout (VDC)  Iout (A)  Eff% 
LM1001-7R
85 - 264VAC
 5.1V
8A
73
LM1301-7R 85 - 264VAC 12V  4A 79
 LM1501-7R 85 - 264VAC 15V  3.4A 78
LM1601-7R 85 - 264VAC 24V  2.0A 81
LM1901-7R 85 - 264VAC 48V  1.0A 81
LM2320-7 85 - 264VAC 12V / 12V  2.0A / 2.0A 77
LM2540-7 85 - 264VAC 15V / 15V  1.7A / 1.7A 78
LM3020-7 85 - 264VAC 5V / 12V / 12V  5.0A / 0.7A / 0.7A 73
LM3040-7 85 - 264VAC 5V / 15V / 15V  5.0A / 0.6A / 0.6A 71
Options
-9             -25°C to +71°C operation
A             Output voltage test Sockets
P             Potentiometer
D0 - D9    Save data signal (See datasheet for options)
V0 - V3    AC Fail signal (See datasheet for options)
Extremly wide operating input voltage ranges from 8 to 385 VDC and 85 to 264 VAC, 47 to 440 Hz
RoHS lead-solder exemption compliant
Class I equipment
Input over- and undervoltage lockout
1, 2, or 3 individually isolated and controlled outputs up to 64 V
Outputs: SELV, no load, overload, short-circuit proof, rectangular current limiting characteristic
Adjustable output voltages with remote on/off
Immunity according to IEC/EN 61000-4-2, -3, -4, -5, -6
Emissions according to EN 55011/55022
PCBs protected by lacquer
Very high reliability
Battery charger models available
Safety according to IEC/EN 60950-1 and UL/CSA 60950-1
The M Series of DC-DC and AC-DC converters represents a
broad and flexible range of power supplies for use in advanced
industrial electronic systems. Features include high efficiency,
reliability, low output voltage noise and excellent dynamic
response to load/line changes due to individual regulation of
each output.

The converter inputs are protected against surges and
transients occuring at the source lines. An input over- and
undervoltage lockout circuit disables the outputs, if the input
voltage is outside the specified range. An inrush current
limitation prevents circuit breakers and fuses from tripping at
switch-on.

All outputs are open- and short-circuit proof, and are protected
against overvoltages by means of built-in suppressor diodes.
The outputs can be inhibited by a logic signal applied to the
connector (pin 2). If the inhibit function is not used, pin 2 should
be connected to pin 23 to enable the outputs.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.

Full input to output, input to case, output to case, and output to
output isolation is provided. The converters are designed and
built according to the international safety standard
IEC/EN 60950-1 and UL/CSA 60950-1, and they have been
approved by the safety agencies TÜV and UL.

The case design allows operation at nominal load up to 71 °C
in a free-air ambient temperature. If forced cooling is provided,
the ambient temperature may exceed 71 °C but the case
temperature should remain below 95 °C under all conditions.

A temperature sensor generates an inhibit signal, which
disables the outputs, when the case temperature TC exceeds
the limit. The outputs automatically recover, when the
temperature drops below the limit.

Various options are available to adapt the converters to
individual applications.

The converters may either be plugged into a 19" rack system
according to IEC 60927-3 or be mounted onto a chassis or a
plate.
Munit---Footprint1Munit---Footprint2

 

 
 
 

 

Related Downloads

M Series Datasheet (772 Kb) M Series Datasheet
Mounting supports (400 Kb) Mounting supports
Cassette & Din Rail Temperature Sensor Datasheet (117 Kb) Cassette & Din Rail Temperature Sensor Datasheet
Mating connectors (221 Kb) Mating connectors
Front panels (96 Kb) Front panels
M Series Agency Approval (72 Kb) M Series Agency Approval
M Series Rohs Certificate (62 Kb) M Series Rohs Certificate
Spacer

Copyright © 2012 Relec  | Site Map  | Terms & Conditions