Mains Input (PFC >0.93), Rugged AC DC Converter
Regulated, 1 or 2 Isolated Outputs
100W AC DC Converters
EN55022 / EN60950 Compliant
-25°C to +71°C Operation
3U x 12HP Eurocassette /19" - Chassis Mount options
|

|
| Part Number |
Input Range (VAC) |
Vout (VDC) |
Iout (A) |
Eff% |
| LS4001-7R |
85 - 264VAC
|
5.1V
|
16A
|
77
|
| LS4301-7R |
85 - 264VAC |
12V |
8A |
81 |
| LS4501-7R |
85 - 264VAC |
15V |
6.5A |
83 |
| LS4601-7R |
85 - 264VAC |
24V |
4.2A |
83 |
| LS5320-7R |
85 - 264VAC |
12V / 12V |
4.0A / 4.0A |
81 |
| LS5540-7R |
85 - 264VAC |
15V / 15V |
3.2A / 3.2A |
81 |
| LS5660-7R |
85 - 264VAC |
24V / 24V |
2.0A / 2.0A |
81 |
|
Options
-9E -40°C to +71°C operation & Electronic Inrush limitation
T Current Sharing
P Potentiometer
D0 - D9 Save data signal (See datasheet for options)
V0 - V3 AC Fail signal (See datasheet for options)
B1 Cooling plate standard case
|
|
Universal AC input range 100 - 240 VAC, 50 - 60 Hz
1 or 2 isolated outputs up to 56.5 VDC
Class I equipment
RoHS lead-solder exemption compliant
Power factor >0.93, harmonics IEC/EN 61000-3-2
Immunity to IEC/EN 61000-4-2, -3, -4, -5, -6
Emissions according to EN 55011/55022
High efficiency
Input over- and undervoltage lockout
Adjustable output voltage with remote on/off
Outputs: SELV, no load, overload and short-circuit proof
Rectangular current limiting characteristic
No derating over entire operating temperature range
PCBs protected by lacquer
Very high reliability |
The S 4000/5000 Series of AC-DC converters represents a
flexible range of power supplies for use in advanced
electronic systems. Features include full power factor
correction, good hold-up time, high efficiency and
reliability, low output voltage noise, and excellent dynamic
response to load/line changes.
The converters are protected against surges and
transients occurring at the source lines. An input over- and
undervoltage lockout circuitry disables the outputs, when
the input voltage is outside of the specified range. Input
inrush current limitation is included for preventing circuit
breakers and fuses from tripping at switch-on.
All outputs are overload, open- and short-circuit proof and
protected by a built-in suppressor diode. The outputs can
be inhibited by a logic signal applied to connector pin 18. If
the inhibit function is not used, pin 18 must be connected
with pin 14 to enable the outputs.
LED indicators display the status of the converter and
allow visual monitoring of the system at any time.
Full input to output, input to case, output to case and
output to output isolation is provided. The converters are
designed and built according to the international safety
standards IEC/EN 60950. They have been approved by
the safety agencies TÜV and UL (for USA and Canada).
The case design allows operation at nominal load up to
71 °C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71 °C but
the case temperature must remain below 95 °C under all
conditions. |
|
| |
| |
| |
|
|
|
|
|