Relec Electronics Ltd

 

ISO 9001


Tel:
+44 (0) 1929 555700
or Contact us here

K (PFC) Series

Mains Input (PFC >0.93), Rugged AC DC Converter
Regulated, 1 or 2 Isolated Outputs
150W AC DC Converters
EN55022 / EN60950 Compliant
-25°C to +71°C Operation
3U x 16HP Eurocassette /19" - Chassis Mount options

    Kunit-image
 
 
 
 
 Part Number Input Range (VAC)  Vout (VDC)  Iout (A)  Eff% 
LK4003-6R
85 - 264VAC
 5.1V
25A
78
LK4301-7R 85 - 264VAC 12V  12A 84
 LK4501-7R 85 - 264VAC 15V  10A 85
LK4601-7R 85 - 264VAC 24V  6A 86
LK5320-7R 85 - 264VAC 12V / 12V 6.0A / 6.0A 81
LK5540-7R 85 - 264VAC 15V / 15V 5.0A / 5.0A 81
LK5660-7R 85 - 264VAC 24V / 24V 3.0A / 3.0A 81
LKP5660-7R 187 - 255VAC 24V / 24V 5.2A / 5.2A 86
Options
-9E          -40°C to +71°C operation & Electronic Inrush limitation
T             Current Sharing
P             Potentiometer
D0 - D9    Save data signal (See datasheet for options)
V0 - V3    AC Fail signal (See datasheet for options)
B1           Cooling plate standard case
Universal AC input range 100 - 240 VAC, 50 - 60 Hz
1 or 2 isolated outputs up to 56.5 VDC
Class I equipment
RoHS lead-solder exemption compliant
Power factor >0.93, harmonics IEC/EN 61000-3-2
Immunity to IEC/EN 61000-4-2, -3, -4, -5, -6
Emissions according to EN 55011/55022
High efficiency
Input over- and undervoltage lockout
Adjustable output voltage with remote on/off
Outputs: SELV, no load, overload and short-circuit proof
Rectangular current limiting characteristic
No derating over entire operating temperature range
PCBs protected by lacquer
Very high reliability
The LK 4000/5000 Series of AC-DC converters represents
a flexible range of power supplies for use in advanced
electronic systems; the LKP models are an extension with
increased output power, but optimized to 230 VAC.
Features include full power factor correction, good hold-up
time, high efficiency and reliability, low output noise, and
excellent dynamic response to load/line changes.

The converters are protected against surges and
transients occurring at the source lines. An input over- and
undervoltage lockout circuitry disables the outputs, when
the input voltage is outside of the specified range. Input
inrush current limitation is included for preventing circuit
breakers and fuses from tripping at switch-on.

All outputs are overload, open- and short-circuit proof and
protected by a built-in suppressor diode. The outputs can
be inhibited by a logic signal applied to connector pin 18. If
the inhibit function is not used, pin 18 must be connected
with pin 14 to enable the outputs.

LED indicators display the status of the converter and
allow visual monitoring of the system at any time.

Full input to output, input to case, output to case and
output to output isolation is provided. The converters are
designed and built according to the international safety
standards IEC/EN 60950. They have been approved by
the safety agencies TÜV and UL (for USA and Canada).

The case design allows operation at nominal load up to
71 °C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71 °C, but
the case temperature must remain below 95 °C under all
conditions. However, higher output power up to 280 W is
possible depending on environmental conditions and
converter model.

An internal temperature sensor generates an inhibit signal,
which disables the outputs, when the case temperature TC
exceeds the limit. The outputs automatically recover, when
the temperature drops below the limit.
Kunit-Footprint-1Kunit-Footprint-2

 

 
 
 

 

Related Downloads

K (PFC) Series Datasheet (628 Kb) K (PFC) Series Datasheet
Mounting supports (400 Kb) Mounting supports
Cassette & Din Rail Temperature Sensor Datasheet (117 Kb) Cassette & Din Rail Temperature Sensor Datasheet
Mating connectors (221 Kb) Mating connectors
Front panels (96 Kb) Front panels
Spacer

Copyright © 2012 Relec  | Site Map  | Terms & Conditions

Powered By Intergage | www.intergage.co.uk