Relec Electronics Ltd

 

ISO 9001

Contact Form - DC DC

Please fill in your details below and we will contact you as soon as possible

  *Indicates a field you must enter.

When you have completed the form, please click the Send Details button ONCE to send

 


Tel:
+44 (0) 1929 555700
or Contact us here

K Series

Wide Input, Rugged DC DC Converter
Regulated, 1, 2 Isolated Outputs
150W DC DC Converters
RIA12 / EN50155 / EN50121 Railway Compliant
-25°C to +71°C Operation
3U x 16HP Eurocassette /19" - Chassis Mount options

    Kunit-image
 
 
 
 
 Part Number Input Range (VDC)  Vout (VDC)  Iout (A)  Eff% 
AK1001-7R
8 - 35VDC
 5.1V
20A
76
AK1301-7R 8 - 35VDC 12V  10A 81
 AK1501-7R 8 - 35VDC 15V  8A 83
AK1601-7R 8 - 35VDC 24V  5A 84
AK2320-7R 8 - 35VDC 12V / 12V  5A / 5A 79
AK2540-7R 8 - 35VDC 15V / 15V  4A / 4A 80
AS2660-7R 8 - 35VDC 24V / 24V   2.5A / 2.5A 80
BK1001-7R
14 - 70VDC
 5.1V
25A
77
BK1301-7R 14 - 70VDC 12V  12A 83
 BK1501-7R 14 - 70VDC 15V  10A 85
BK1601-7R 14 - 70VDC 24V  6A 86
BK2320-7R 14 - 70VDC 12V / 12V  6A / 6A 80
BK2540-7R 14 - 70VDC 15V / 15V  5A / 5A 82
BK2660-7R 14 - 70VDC 24V / 24V  3A / 3A 82
CK1001-7R
28 - 140VDC
 5.1V
25A
77
CK1301-7R 28 - 140VDC 12V  12A 83
 CK1501-7R 28 - 140VDC 15V  10A 84
CK1601-7R 28 - 140VDC 24V  6A 85
CK2320-7R 28 - 140VDC 12V / 12V  6A / 6A 80
CK2540-7R 28 - 140VDC 15V / 15V  5A / 5A 82
CK2660-7R 28 - 140VDC 24V / 24V  3A / 3A 82
DK1001-7R
44 - 220VDC
 5.1V
25A
79
DK1301-7R 44 - 220VDC 12V  12A 84
 DK1501-7R 44 - 220VDC 15V  10A 86
DK1601-7R 44 - 220VDC 24V  6A 86
DK2320-7R 44 - 220VDC 12V / 12V  6A / 6A 81
DK2540-7R 44 - 220VDC 15V / 15V  5A / 5A 82
DK2660-7R 44 - 220VDC 24V / 24V  3A / 3A 83
LK1001-7R
88 - 372VDC
 5.1V
25A
78
LK1301-7R 88 - 372VDC 12V  12A 83
 LK1501-7R 88 - 372VDC 15V  10A 84
LK1601-7R 88 - 372VDC 24V  6A 85
LK2320-7R 88 - 372VDC 12V / 12V  6A / 6A 80
LK2540-7R 88 - 372VDC 15V / 15V  5A / 5A 81
LK2660-7R 88 - 372VDC 24V / 24V  3A / 3A 81
Options
-9             -40°C to +71°C operation
E             Electronic inrush current limitation
P             Potentiometer
T             Current sharing
D0 - D9    Save data signal (See datasheet for options)
V0 - V3    AC Fail signal (See datasheet for options)
B1, B2     Base plate options
Input voltage ranges from 8 to 385 VDC
1or 2 isolated outputs up to 48 VDC
Class I equipment
RoHS lead solder exemption compliant
Extremely-wide input voltage range
Input over- and undervoltage lockout
Efficient input filter and built-in surge and transient suppression circuitry
Outputs: SELV, no-load, and short-circuit proof
No derating over entire operating temperature range
PCBs coated with protective lacquer
Very high reliability

The K Series AC-DC and DC-DC converters represents a broad
and flexible range of power supplies for use in advanced
electronic systems. Features include high efficiency, high
reliability, low output voltage noise and excellent dynamic
response to load/line changes. LK models can be powered by
DC or AC with a wide-input frequency range (without PFC).

The converter inputs are protected against surges and
transients. An input over- and undervoltage lockout circuitry
disables the outputs if the input voltage is outside of the
specified range. Certain types include an inrush current limiter
preventing circuit breakers and fuses from tripping at switch-on.

All outputs are open- and short-circuit proof and are protected
against overvoltages by means of built-in suppressor diodes.
The outputs can be inhibited by a logic signal applied to pin 18
(i). If the inhibit function is not used, pin 18 must be connected
with pin 14 to enable the outputs.

LED indicators display the status of the converter and allow for
visual monitoring of the system at any time.

Full input-to-output, input-to-case, output-to-case and output-tooutput
isolation is provided. The converters are designed and
built according to the international safety standards IEC/EN
60950 and EN50155. They have been approved by the safety
agencies TÜV and UL (for USA and Canada).

The case design allows operation at nominal load up to 71 °C in a
free-air ambient temperature. If forced cooling is provided, the
ambient temperature may exceed 71 °C, but the case temperature
must remain below 95 °C under all conditions.

A temperature sensor generates an inhibit signal, which disables
the outputs if the case temperature Tc exceeds the limit. The
outputs are automatically re-enabled when the temperature drops
below the limit.

Various options are available to adapt the converters to individual
applications.

The converters may either be plugged into a 19" rack system
according to IEC 60297-3, or be chassis mounted. They are ideally
suited for Railway applications.

Kunit-Footprint-1Kunit-Footprint-2Kunit-Footprint-3

 

 
 
 

 

Related Downloads

K Series Datasheet (592 Kb) K Series Datasheet
Mounting supports (400 Kb) Mounting supports
Cassette & Din Rail Temperature Sensor Datasheet (117 Kb) Cassette & Din Rail Temperature Sensor Datasheet
Mating connectors (221 Kb) Mating connectors
Front panels (96 Kb) Front panels
K Series Rohs Certificate (129 Kb) K Series Rohs Certificate
K&S Series Agency Approval (2776 Kb) K&S Series Agency Approval
Spacer

Copyright © 2012 Relec  | Site Map  | Terms & Conditions

Powered By Intergage | www.intergage.co.uk