Relec Electronics Ltd

 

ISO 9001


Tel:
+44 (0) 1929 555700
or Contact us here

FNR-5 Series subracks

Universal Mains Input
AC DC Front End system
5000W AC DC Rack Mount Converters

0°C to +70°C Operation
Internal Fan Cooled
5.6" x 12.0" x 1.6" cassette and 1U Subrack

 FNR Shelf image
 
 
 
Part Number Input Range Vout (VDC) Iout (A) Power Supply
FNR-5-12G 90 - 265 VAC  7.0 - 12.0V
12V Standby
250A
355A
FNP600-12G
FNP850-12G
FNR-5-48G 90 - 265 VAC 44 - 50.5V
12V Standby
62A
105A
FNP600-12G
FNP1000-12G
RoHS lead free solder and lead solder exempted products are available
High density front-ends 10.5 to 16.1 W/in3
Universal input voltage range (90-264 VAC) with PFC
1U or 2U height configurations
Droop current share with ORing FETs
I2C interface status and control
Standby voltage of 12 VDC @ 0.5 A
Overtemperature, overload, and overvoltage protection
Status LEDs: AC OK, DC OK, Overtemperature
FNP850-12 model has airflow direction from front-to-rear or from rear-to-front (-12R model)
ON/OFF Enable switch - shuts OFF Vo1; Vaux and fan are operational.
The FNP600/850/1000 power factor corrected (PFC) front ends provide (depending on model) either a 12 VDC or a 48 VDC output for telecom, datacom, and other distributed power applications. Their small 1U by 2U size allows for configurations of either height in hot-swap redundant systems while their internal fan and cooling design permits wide use with reliable operation.

Status is provided with front panel LEDs, logic signals, and via the I2C management interface bus. In addition, the I2C bus can enable the power supply, control fan speed, and on the 12 VDC models it allows for adjusting the output voltage from 7 to 12 VDC. This powerful feature allows the same power supply to be used in various applications where bus voltages driving isolated dc-dc converters and POL regulators may be different.

Also, the FNP850-12R is uniquely designed with airflow from the rear of the power supply to the front. This airflow direction supports those critical applications where space limitations and/or higher ambient temperatures near the rear of the rack system, prohibit the discharge of higher temperature airflow from regular front-to-rear cooled power supplies.

The FNP600/850/1000's meet international safety requirements and are CE marked to the Low Voltage Directive (LVD).
FNR-5 Footprint

 

 
 
 

 

Related Downloads

FNP600 850 1000 Datasheet (4192 Kb) FNP600 850 1000 Datasheet
FNP600 850 1000 Agency Approval (4203 Kb) FNP600 850 1000 Agency Approval
FNR FXR Shelves Agency Approvals (1011 Kb) FNR FXR Shelves Agency Approvals
Spacer

Copyright © 2012 Relec  | Site Map  | Terms & Conditions