| Rated Current |
6 - 1100 A |
| Ratings Voltage |
480 - 520 VAC; 50/60 Hz |
| Leakage Current |
Standard < 0.5 mA (250 V / 60 Hz) |
| Approval for |
6 - 1100 A @ Ta 40 (75) °C / 520 VAC;
50 Hz |
| Overload Current |
1.5 x Ir |
| Dielectric Strength for 480V AC |
2.25 kVDC between L-L
3 kVDC between L-PE |
| Dielectric Strength for 520V AC |
2.25 kVDC between L-L
4 kVDC between L-PE
Test voltage (2 sec) |
| Allowable Operation Temp. |
-25 °C to 100 °C |
| Climatic Category |
25/100/21 acc. to IEC 60068-1 |
| Protection Class |
Suitable for appliances with protection
class 1 acc. to IEC 61140 |
| Terminal |
Quick connect terminals 6.3 x 0.8 mm
or screw terminals
Current >24 A requires screw terminals |
| Material: Housing |
Alu. anodised / Stainless Steel |
| Line Filter |
Standard & Industrial Version, IEC 60939, IEC
60601‑1, UL 1283, UL 544, EN 133
200, CSA C22.2 no. 8 |
| MTBF |
> 200'000 h acc. to MIL-HB-217 F |